![Danfoss iSave 50 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/danfoss/isave-50/isave-50_operating-manual_3487204053.webp)
Design guide | Membrane cleaning of the RO-system with iSave ERD
53
180R9357 | AQ265943679828en-00100
2
IOM iSave 50 - 70 | 0
3
.202
3
Below procedures are general guidelines for
the membrane cleaning of SWRO-systems with
the Danfoss iSave. Procedure details may differ
depending on the system design.
The numbers marked in () refer to the
diagram’s below.
The purpose of membrane cleaning is to reduce
scaling and fouling in the membranes. For opti-
mal performance specific chemicals are required,
depending on the cause of the contamination.
After chemical treatment the system must be
flushed with fresh water. The flushing water,
coming out of the membranes, may consist of a
large amount of suspended inorganic particles. It
is important to assure that these particles are not
fed into the iSave(s) or pump(s).
NB! It is recommended to disconnect the
piping from the “HP in” of the iSave and flush
the contaminated water from the membranes
directly to drain. By disconnecting the pipes
there will be no accumulation of
contaminations in the HP-piping and
HP-valves.
See P&ID no 2.
Membrane cleaning
The procedures below are based on Dow’s
Cleaning and Sanitization: Cleaning steps
described in Dow’s Form No. 609-02090-1005.
Other procedure may be used depending on the
membranes used.
Below procedure is according P&ID no 1.
1. Stop the high-pressure pump(s) (4), and stop
the iSave(s) (11).
2. Stop the seawater supply pump (A).
3. Close valve (9 and 27) and open valve (16 and
28), and feed cleaning solution through valve
(7).
4. Pump mixed cleaning solutions to the vessel
at conditions of low flow rate and low pressure
to displace the process water. Use only
enough pressure to compensate for the
pressure drop from feed to concentrate.
The pressure should be low enough that
essentially no or little permeate is produced.
A low pressure minimizes re-deposition of
dirt on the membrane. Dump the brine/
concentrate to prevent dilution of the
cleaning solution.
5. Recycle: After the process water is displaced,
cleaning solution will be present in the
concentrate/ brine stream. Recycle the
cleaning solution from the piping to the
cleaning solution tank.
6. Turn of the pump and allow the elements
to soak.
Содержание iSave 50
Страница 20: ...Operating guide iSave 50 70 20 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 23: ...Data sheet iSave Energy Recovery Device iSave 50 iSave 70 hpp danfoss com...
Страница 45: ...Design guide iSave Energy Recovery Device Start and stop of the SWRO with iSave hpp danfoss com...
Страница 50: ...Danfoss DCS im 2020 01 180R9213 521B1164 DKCFN PI 003 F8 02 50...
Страница 51: ...Design guide Energy Recovery Device iSave Membrane cleaning of RO system hpp danfoss com...
Страница 56: ...Danfoss DCS im 2017 09 521B1165 DKCFN PI 00 G6 02 56...
Страница 57: ...ro solutions com Design Guide APP pumps and iSave overload protection hpp danfoss com...
Страница 65: ...Design Guide APP and iSave overload protection 65 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 66: ...Danfoss DCS im 2018 08 180R9372 521B1412 DKCFN PI 003 O2 02 66...
Страница 74: ...Danfoss DCS im 2019 05 180R9084 521B0540 DKCFN PI 000 D7 02 74...
Страница 75: ...Parts list Energy recovery device iSave 50 70 hpp danfoss com...
Страница 86: ...86 Danfoss DCS im 2021 03 180R9392_AX299849991270en 000701...
Страница 87: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 91: ...91 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...