Design Guide | APP and iSave overload protection
59
180R9357 | AQ265943679828en-00100
2
IOM iSave 50 - 70 | 0
3
.202
3
2.
APP pump and iSave
overload protection
When protecting the pump and iSave against
overload
both the maximum torque and
maximum pressure must be taken into
account.
- Maximum allowable operation torque is the
maximum torque the product can handle in
normal operation.
- Maximum allowable operation torque is the
maximum torque the product need in a
specificl operation.
2.1 Maximum torque
Start up:
•
Ramp up speed from 0 to set-point
•
The starting torque must not exceed maxi-
mum Starting Torque according to chapter 5.
Ongoing operating:
•
Continuously the torque must not exceed
120% of maximum Allowable Operating
Torque for more than 30 sec.
•
Periodically the torque can for a very short
time go up to maximum Starting torque.
Example #1
0
20
40
60
80
100
120
140
160
0
10
20
30
40
50
60
70
80
90
100
100
100
100
100
Pe
rc
en
t
of
m
ax
lo
ad
Percent
of
design
speed
Load
Protection
VFD
setting:
According
to
maximum
allowable
operating
torque
Torque
Max
starting
torque
30
sec
20%
overload
30
sec
20%
overload
Max
allowable
operating
torque
0
20
40
60
80
100
120
140
160
0
10
20
30
40
50
60
70
80
90
100
100
100
100
100
Pe
rc
en
t
of
m
ax
lo
ad
Percent
of
design
speed
Load
Protection
VFD
setting:
According
to
actual
load
Torque
Max
starting
torque
30
sec
20%
overload
30
sec
20%
overload
Maximum
Operating
torque
Maximum
allowable
operating
torque
Example #2
Содержание iSave 50
Страница 20: ...Operating guide iSave 50 70 20 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 23: ...Data sheet iSave Energy Recovery Device iSave 50 iSave 70 hpp danfoss com...
Страница 45: ...Design guide iSave Energy Recovery Device Start and stop of the SWRO with iSave hpp danfoss com...
Страница 50: ...Danfoss DCS im 2020 01 180R9213 521B1164 DKCFN PI 003 F8 02 50...
Страница 51: ...Design guide Energy Recovery Device iSave Membrane cleaning of RO system hpp danfoss com...
Страница 56: ...Danfoss DCS im 2017 09 521B1165 DKCFN PI 00 G6 02 56...
Страница 57: ...ro solutions com Design Guide APP pumps and iSave overload protection hpp danfoss com...
Страница 65: ...Design Guide APP and iSave overload protection 65 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 66: ...Danfoss DCS im 2018 08 180R9372 521B1412 DKCFN PI 003 O2 02 66...
Страница 74: ...Danfoss DCS im 2019 05 180R9084 521B0540 DKCFN PI 000 D7 02 74...
Страница 75: ...Parts list Energy recovery device iSave 50 70 hpp danfoss com...
Страница 86: ...86 Danfoss DCS im 2021 03 180R9392_AX299849991270en 000701...
Страница 87: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 91: ...91 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...