MDC Legend - single pumps
Wrench size and torque
Item
Description
Wrench size
Torque
D065
O-ring plug
3/16 internal hex
12 N•m [9 lbf•ft]
D084
Screen
-
-
D098
Ring
-
-
D200
Feedback pin
13 mm deep well socket
22.5-27.5 Nm [16.6-20.3 lbf•ft]
D250
Cap screw
5 mm internal hex
13.3 Nm [9.8 lbf•ft]
D80
Solenoid
-
-
D81
O-ring
-
-
D750
Neutral start switch
-
-
D751
O-ring
-
-
D735
Plug
3/4 inch
30 Nm [22 lbf•ft]
F00A
Servo orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
F00B
Servo orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
F00P
Supply orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
F00T
Tank orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
MDC Control Assembly
Ensure you install dowel pins (D300) in housing before installing control.
The pump will lose control, causing a potentially hazardous situation.
If a feedback pin comes off during operation, ensure the feedback pin is properly torqued before
continuing with reassembly.
1. Install a new gasket (D150).
2. If previously removed, install orifices using a 3 mm internal hex wrench and torque to 2.5 N•m [1.8
lbf•ft].
3. Install the control module and six cap screws (D250).
4. Using a 5 mm internal hex wrench, torque the cap screws (D250) to 13.3 N•m [9.8 lbf•ft].
Torque sequence
2
3
4
5
6
1
Service Manual
H1P 069—H1P 280 Axial Piston Single Pumps
Minor Repair