Servo Adjustment
Servo Adjustment
E350
Servo can
locking bolt
E300
Servo can
locking plate
P106 490E
E300
Servo cylinder clamp
E350
Servo cylinder clamp bolt
1. Run prime mover at 1800 min
-1
(rpm).
2. If using a PWM signal, ensure the signal is off.
3. Check the servo pressure gauges, ensure the differential between M4 and M5 is less than 2.5 bar [36
psi].
4. Using a 3/4 in deep socket, unthread both servo cylinders 2-3 turns.
This step ensures the servo cylinders have no contact with the servo piston.
5. Stroke the pump by turning the control eccentric screw (or supplying current to solenoid C1) until the
servo pressure at port M4 is 1 to 2 bar [14– 29 psi] greater than at port M5 and the system pressure
gauges indicate displacement.
Pressure should be greater at port MA for clockwise rotation, or MB for counterclockwise rotation.
This also indicates the servo piston is in contact with the servo cylinder on side M5.
6. Maintain servo pressure differential between 1-2 bar [14-29 psi] during this step. Slowly thread the
servo cylinder on the M5 side in until the system pressure differential starts to decrease. Continue
turning the servo cylinder in until the system delta pressure results in no machine movement.
System delta pressure (ports MA to MB or MC to MD) between 3-4 bar typically does not cause
machine movement. If service of a pump is not performed on the machine, validation of machine
movement must be checked upon machine start up.
7. Repeat steps 1. to 5. but stroke the pump in the opposite direction by turning the eccentric screw in
the opposite direction, or by supplying current to solenoid C2 to complete setting neutral.
Reverse gauge locations (M4 for M5, MB for MA etc.) from those stated above since the pump is now
stroking the other direction.
8. Set neutral for the rear pump by repeating steps 1. to 6. on the rear pump. Remember that the rear
pump is a mirror image of the front pump and therefore the locations of the servo gauge ports
(M4/M5) and the control solenoids (C1/C2) are opposite.
9. Remove all gauges and replace gauge port plugs.
You can find wrench sizes and plug torques in the
on page 66.