Removal
Using a 27 mm (V10-1) or a 1 in (V10-2) wrench, remove the charge pressure relief valve. Discard the
O-rings (V10A).
Inspection
Inspect the sealing surfaces of the pump and charge pressure relief valve for nicks or scratches,
replace components as necessary.
Reassembly
1. Lubricate and install new O-rings (V10A).
2. Install the charge pressure relief valve (V10). Torque to 52 Nm [38 lbf•ft].
3. Operate vehicle/machine through full range of controls to ensure proper operation.
Charge pressure relief valve
P109568
V10-1
V10A
V10-2
V10A
V10-3
V10A
Service Manual
H1 45/53/60/68 Tandem Closed Circuit Axial Piston Pumps
Minor repair
62 |
©
Danfoss | June 2018
520L0928 | AX00000103en-US0303