The model code on the serial plate gives the factory setting of the PL (Pressure Limiter). The PL setting
is referenced to charge pressure. Subtract charge pressure from system pressure gauge readings to
compute the effective PL setting.
6. Repeat steps four and five until you reach the desired PL setting. After adjustment, torque the locknut
(L024). Do not over torque.
7. Shut down the prime mover. Remove gauges and replace plugs.
Pressure limiter settings
Pressure limiter setting
HPRV setting
150
200
180
230
200
250
230
280
250
300
280
330
300
350
330
380
350
400
380
420
Pressure limiter setting
HPRV setting
400
450
410
420
430
480
440
450
460
510
470
480
Engaging the Bypass Function (060/068 only)
Use this procedure to bypass the pump to allow moving the vehicle/machine short distances when you
cannot start the prime mover.
C
Caution
It is possible to damage the drive motor(s) by operating in bypass mode without charge pressure. Move
the vehicle/machine at a speed not more than 20% of maximum for a duration not exceeding 3 minutes.
1. To open the HPRVs (A and B), rotate three revolutions counter clockwise using a 22mm hex wrench.
Do not rotate more than 3 revolutions, leakage will result.
2. To close the HPRVs, rotate them clockwise until seated. Torque to 70 N•m [52 lbf•lb].
Service Manual
H1 45/53/60/68 Tandem Closed Circuit Axial Piston Pumps
Adjustments
38 |
©
Danfoss | June 2018
520L0928 | AX00000103en-US0303