045-053 tandem schematic
C1
C1
C2
C2
M14
M14
CW
F00B F00A
F00B
F00A
A
B
MA
E C D MD
MB
M3
L3
MC
M4
M5
M4
M5
PTO
X7
060/068 schematic
M5
M4
A
MA
MD
D
B
MB
MC
C
M5
M4
H1 Tandem
E
M3
ccw
flow out B
flow out D
C1
C2
M14
C1
C2
M14
1
2
Supply/Ground
CONTROL SOLENOID C1
Ground/Supply
1
2
Supply/Ground
Ground/Supply
CONTROL SOLENOID C2
1
2
Supply/Ground
CONTROL SOLENOID C2
Ground/Supply
1
2
Supply/Ground
Ground/Supply
CONTROL SOLENOID C1
X7
1 2
Supply/Gr
ound
Gr
ound/Supply
CC
O SOLENOID
1 2
Supply/Gr
ound
Gr
ound/Supply
BR
AKE SOLENOID
L1
L3
P109541
Solenoid data
Description
12 V
24 V
Minimum supply voltage
9 V
DC
18 V
DC
Maximum supply voltage (continuous)
16 V
DC
32 V
DC
Service Manual
H1 45/53/60/68 Tandem Closed Circuit Axial Piston Pumps
Operation
18 |
©
Danfoss | June 2018
520L0928 | AX00000103en-US0303