3. If machine is towable with HPRVs opened three turns and if wheels are locked (not towable) with
HPRV valves closed, bypass function is working correctly.
Engaging the bypass function
P109554
060/068
A
B
Legend
Item
Description
Wrench size
Torque
A
HPRV valve for rear pump
22 mm
70 N•m [52 lbf•lb]
B
HPRV valve for front pump 22 mm
70 N•m [52 lbf•lb]
Displacement limiter adjustment
An optional displacement limiter is located on each side of the pump housing. The maximum
displacement can be limited in either direction.
Displacement limiters are not pre-set by the factory but are installed to minimize the extension of the
adjustment screw while not limiting the maximum displacement of the pump. A small amount of
clockwise screw adjustment is required before the 100% displacement condition is reached.
1. Mark servo cylinder location in case it rotates during displacement limiter adjustment.
2. Loosen the locknut (E550).
3. Rotate the adjusting screw (E450) based on the following table. Rotating the adjusting screw
clockwise decreases the maximum displacement of the pump while rotating the adjusting screw
counterclockwise increases the maximum displacement.
4. After establishing the desired maximum displacement setting, hold adjusting screw in place and
tighten the locknut. Torque to 23 N•m [17 lbf•ft].
C
Caution
Be sure servo cylinder does not rotate when displacement limiter locknut (E550) is torqued.
Service Manual
H1 45/53/60/68 Tandem Closed Circuit Axial Piston Pumps
Adjustments
©
Danfoss | June 2018
520L0928 | AX00000103en-US0303 | 39