![background image](http://html1.mh-extra.com/html/danfoss/control-c-2/control-c-2_operators-manual_3398135056.webp)
0021.91
mm
Current calliper value.
If the message
“mm/inch? mm” is displaced, the
pre-set unit of the calliper does not comply with the
pre-set unit of the machine. Correct the measuring
unit of the calliper or the machine.
If the message “Error mm” is displayed, no calliper
is identified, or the communication between the cal-
liper and the control is disrupted.
Calliper settings.
See “Pre-set calliper” in Section 5.
Displays the relevant measuring points (front, cen-
tre, back). The recorded values are also saved in
the UDL under their relevant letter (A - L).
Definition of the triangles:
•
Grey: outstanding measurement.
•
Red: point to be measured.
•
Green: point already measured.
Back to forming parameter screen.
or foot switch
(1)
Accept measurement and proceed to next measur-
ing point. Continue with measuring result screen af-
ter the last measurement.
The measured result in shown in the last screen: