82
Piranha4 4K Camera Color User's Manual
03-032-20180-01
Teledyne DALSA
Bau d 9600
Bau d 19200
Bau d 57600
Bau d 115200
Bau d 230400
Bau d 460800
Bau d 921600
Bau d 9600
Bau d 19200
Bau d 57600
Bau d 115200
Bau d 230400
Bau d 460800
Bau d 921600
Bau d rate is 9600
Bau d rate is 19200
Bau d rate is 57600
Bau d rate is 115200
Bau d rate is 230400
Bau d rate is 460800
Bau d rate is 921600
Serial Port Parity
d eviceSerialPortParity
Sets the p arity checking typ e on the selected
serial p ort.(RO)
1.00
Beginner
DFN C
N one
N one
Parity checking is d isabled
Data Size
d eviceSerialPortDataSize
Sets the bits p er character (bp c) to u se (RO).
1.00
Beginner
DFN C
Eight Bits
bp c8
Use 8 bits p er character
Stop Bits
d eviceSerialPortN u m berOf
Stop Bits
Sets the nu m ber of stop bits to u se.
1.00
Beginner
DFN C
Stop bits1
Stop bits1
Use 1 stop bit
File Access Control Category
The File Access control in Cam Exp ert allow s the u ser to qu ickly u p load variou s d ata files to the
connected P4. The su p p orted d ata files are for P4 firm w are u p d ates, Flat Field coefficients. LUT d ata
tables, and a cu stom im age for u se as an internal test p attern.
Featu res listed in the d escrip tion table bu t tagged as
Invisible
are u su ally for Teled yne DALSA or third
p arty softw are u sage—not typ ically need ed by end u ser ap p lications.
All manuals and user guides at all-guides.com