Piranha4 4K Color Camera User's Manual
95
Teledyne DALSA
03-032-20180-01
Full N ame
Load Pixel Coefficients
Mnemonic
LPC
Argument(s)
Set selector
0. Factory set
1-8. User sets
D escription
Load u ser set
N otes
Load s FPN coefficients and PRN U coefficients from a u ser set ( only
coefficeints, no other cam era p aram eters)
Full N ame
Reset Camera
Mnemonic
RC
Argument(s)
D escription
Resets the cam era to the saved u ser d efau lt settings. These settings are saved u sing the
u sd com m and .
N otes
Full N ame
Set Flatfield ROI
Mnemonic
ROI
Argument(s)
First p ixel
1 to 4096*
Last p ixel
1 to 4096*
D escription
Flat field region of interest
N otes
Sp ecifies the p ixels that CCF and CPA w ill calibrate
o
Pixel coefficients ou tsid e this region are not changed
Last p ixel m u st be greater than or equ al to first p ixel
*4080 active p ixels, the last 16 p ixels are inactive
Full N ame
Reset Flatfield Coefficients
Mnemonic
RPC
Argument(s)
D escription
Reset all u ser FPN valu es to zero and all u ser PRN U coefficients t o one
N otes
Full N ame
Set AOI Count
Mnemonic
SAC
Argument(s)
Number of AOI‘s
1 to 4
D escription
Set AOI Cou nter
N otes