Piranha4 4K Color Camera User's Manual
23
Teledyne DALSA
03-032-20180-01
Data Connector: Camera Link
The cam era u ses tw o Cam era Link SDR26 cables transm itting the Cam era Link Base, Med iu m , Fu ll, or
Deca configu ration. The figu re below show s th e SDR26 Cam era Link Connector and the tables that follow
list the Cam era Link configu ration s.
For d etailed inform ation on Cam era Link p lease refer to the Cam era Link Road Map available from the
Know led ge Center
on the Teled yne DALSA Web site.
Figure 9. SDR26 Camera Link Connector
Data 2
Control / Data 1
Camera
Connector
Right Angle
Frame Grabber
Connector
Channel Link
Signal
Camera
Connector
Right Angle
Frame Grabber
Connector
Channel Link
Signal
1
1
inner shield
1
1
inner shield
14
14
inner shield
14
14
inner shield
2
25
Y0-
2
25
X0-
15
12
Y0+
15
12
X0+
3
24
Y1-
3
24
X1-
16
11
Y1+
16
11
X1+
4
23
Y2-
4
23
X2-
17
10
Y2+
17
10
X2+
5
22
Yclk-
5
22
Xclk-
18
9
Yclk+
18
9
Xclk+
6
21
Y3-
6
21
X3-
19
8
Y3+
19
8
X3+
7
20
100 ohm
7
20
SerTC+
20
7
term inated
20
7
SerTC-
8
19
Z0-
8
19
SerTFG-
21
6
Z0+
21
6
9
18
Z1-
9
18
CC1-
22
5
Z1+
22
5
CC1+
10
17
Z2-
10
17
CC2+
23
4
Z2+
23
4
CC2-
11
16
Zclk-
11
16
CC3-
24
3
Zclk+
24
3
CC3+
12
15
Z3-
12
15
CC4+
25
2
Z3+
25
2
CC4-
13
13
inner shield
13
13
inner shield
26
26
inner shield
26
26
inner shield
Note
:
*Exterior Overshield is connected to the shells of the connectors on both ends. Unused pairs should be terminated in 100 ohms at
both ends of the cable. Inner shield is connected to signal ground inside camera
Camera Link Bit Definitions
Signal
Configuration
CC1
EXSYN C
CC2
Sp are
All manuals and user guides at all-guides.com