201 Daktronics Drive PO Box 5128 Brookings, SD 57006
tel 800-843-5843 fax 605-697-4700
www.daktronics.com
VIP-4060
Video Image Processor
Operator’s Manual
DD1804047
Rev 09—08 May 2015
Страница 1: ...201 Daktronics Drive PO Box 5128 Brookings SD 57006 tel 800 843 5843 fax 605 697 4700 www daktronics com VIP 4060 Video Image Processor Operator s Manual DD1804047 Rev 09 08 May 2015...
Страница 2: ...torage and retrieval systems without written permission of the publisher Daktronics is a registered trademark of Daktronics Inc Firefox is a registered trademark of Mozilla Foundation Internet Explore...
Страница 3: ...ernet Protocol IP Address 6 2 3 Computer System Requirements 6 2 4 Software Installation 7 Detecting Installing Silverlight Application 7 Detection 7 Installation 7 Installing Java Software 8 Enabling...
Страница 4: ...Manual 24 GPS 24 ERTD 24 Color Adjustment 25 Source Target 26 Source 26 Input Video Status 26 4 2 Tools Tab 27 Set Time Date 27 Run File Check 27 Reset Display 28 Clear Memory 28 System Status Informa...
Страница 5: ...ng it Terms that describe commonly used personal computer operations are used frequently in this manual 1 1 Daktronics Contact Information Users can access the VIP 4060 Operator s Manual via the blue...
Страница 6: ......
Страница 7: ...ting a video feed to the VIP 4060 system The type of video feed determines which will be used In stand alone systems the options are generally 720p SDI or DVI Daktronics supplied control systems use V...
Страница 8: ...cable to the network port on the VIP 4060 Refer to Figure 6 2 Connect the other end of the cable to the computer or network Power To connect power to the VIP 4060 follow the steps below 1 Connect the...
Страница 9: ...information or to access the download Figure 9 DisplayFind Utility Window A red X is shown next to The Current User Is Not An Administrative User On This Computer if the user does not have administrat...
Страница 10: ...4060 controllers are found use the Media Access Control MAC address or Dynamic Host Configuration Protocol DHCP name from the label on the back of the VIP 4060 to select the appropriate system The ad...
Страница 11: ...t application is not installed on the host machine the user will see the Install Microsoft Silverlight icon as shown in Figure 14 To install the Silverlight application follow the steps below 1 Click...
Страница 12: ...software and proceed to the login instructions Note Daktronics recommends disabling the Java cache Refer to Section 6 2 Enabling JavaScript Language and Java Software JavaScript language must be enabl...
Страница 13: ...All Add Ons 3 Navigate to Oracle America Inc in the results window using the scroll bar on the right 4 Select the line for Java Plug in 1 60_xx and click the Enable button in the lower right corner of...
Страница 14: ...2 Open an internet browser window and enter http DCHP into the address bar i e http M41053 or http DAKT020345 This opens the login dialog box shown in Figure 25 3 Type Dak in the Username text box The...
Страница 15: ...ub tab 3 Uncheck the Use Default Configuration port check box Refer to Figure 29 4 Enter the new configuration port number in the Configuration Port text box or use the arrows to change the number Not...
Страница 16: ...e display adjustment controls Dimming To manually adjust dimming choose Manual from the Dimming mode drop down list and use the slider to select the preferred value Refer to Figure 34 To automatically...
Страница 17: ...uration files follow the steps below 1 Click the Backup display configuration icon to open the Save As window Refer to Figure 36 2 Choose the Save As storage location by using the Look In drop down li...
Страница 18: ......
Страница 19: ...the user Header Bar Right Column Help Manual About Communication Settings Left Column Presentation Area Figure 38 Remote Display Configuration Screen 3 2 Communication Indicators This section details...
Страница 20: ...ings icon opens the Settings window which provides quick access to the Timeouts tab and the Configuration tab Timeouts Adjust the Communication Timeout setting by increasing or decreasing the length o...
Страница 21: ...his feature provides the ability to reload a stored configuration file from the Backup display configuration control To reload a stored configuration file follow the steps below 1 Click the Load displ...
Страница 22: ...e primary VIP interface to locate the green Active switch in the upper right corner Refer to Figure 46 Click the switch to change this Active VIP system to Inactive 3 Click the Send Configuration butt...
Страница 23: ...y Control Tab Features Input video status Refer to the table below for a description of the Display Control tab features Feature Description Zoom slider Adjusts the monitor image larger or smaller Inp...
Страница 24: ...s no longer an adjustable value in the color adjustment tools Note Test patterns play immediately when selected interrupt any currently playing video and continue to run until a new selection is made...
Страница 25: ...tom Image Custom Image allows the user to load and display an image with the same resolution as the video display Selecting Custom Image triggers the Open window as shown in Figure 51 From the Open wi...
Страница 26: ...ication via Port B the module s connected to that PLR will turn green PL6 EPLD tests the EPLD firmware If all firmware is the same all the modules will turn green If there are modules with different f...
Страница 27: ...ected to those modules will turn red PL5 Micro tests the Micro firmware If all firmware is the same all the modules will turn green If there are PLRs with different firmware all the modules connected...
Страница 28: ...Moving the slider bar to the right adjusts the maximum light out of the display and adjusts all color levels equally by the percentage indicated For example 100 percent means a full white image shows...
Страница 29: ...ion Brightness Adjusts the overall gray level of the display Increasing brightness makes blacks appear gray Reducing brightness blackens low level colors The default is a neutral 50 percent Contrast A...
Страница 30: ...tion about the currently selected video source is located to the right of the presentation area Refer to Figure 65 The fields listed in this window are described in the table below Information Descrip...
Страница 31: ...feature is used to troubleshoot corrupted files on the VIP 4060 system If prompted to run the file check when logging in to the VIP 4060 the check should be performed as soon as possible The display...
Страница 32: ...d prior to choosing either the Run File Check or Reset Display functions System Status Information System status information is shown on the right side of the Tools tab Refer to Figure 66 Information...
Страница 33: ...uld contact Daktronics Technical Services before modifying the settings in these tabs Note Changes made under the Panel Adjustment Configuration and Advanced tabs may adversely affect display operatio...
Страница 34: ......
Страница 35: ...ools primary through community junior colleges religious organizations municipal clubs and community centers 877 605 1115 Universities and professional sporting events live events for auditoriums and...
Страница 36: ...prevent damage during shipping Electronic components such as printed circuit boards should be placed in an anti static bag before boxing Daktronics does not recommend packing peanuts when shipping 4...
Страница 37: ...allows a change of ratio between the brightest red component and weakest red component Refresh Rate Number of times per second a display is updated or repainted NTSC signals have a refresh rate of 30...
Страница 38: ......
Страница 39: ...0 Specification VIP 4060 Physical Size 8 89 cm 3 5 high 22 23 cm 8 75 wide 31 12 cm 12 25 deep Weight 3 24 kg 7 15 lb Video Compatibility DVI VGA VGA SXGA HD SDI full 720p 1080p 30fps Display Inputs D...
Страница 40: ......
Страница 41: ...Supplementary Documents 37 Appendix B Supplementary Documents This section includes the following DD1733958 VIP 4060 Quick Guide...
Страница 42: ......
Страница 43: ...eir corresponding ports The cables will click into place when seated properly Refer to Figure 2 Note Remove fiber dust covers from the cables prior to inserting into ports Connecting Video Source SDI...
Страница 44: ...ommunication Setup Connecting to VIP 4060 1 Dowload the DisplayFind application a Navigate to dakfiles daktronics com b Click venus1500 Utils DisplayFind DisplayFind exe c Click Run to download the pr...
Страница 45: ...ons from the Tools menu drop down list 2 Click the drop down arrow for the Show list and select All add ons Refer to Figure 10 3 Navigate to Oracle America Inc in the results window 4 Select the line...
Страница 46: ...a password after initial configuration Once a password is configured the new password needs to be entered into the Password text box during login Note Do not lose the password losing it requires a se...
Страница 47: ...values are controlled via Enhanced Real Time Data ERTD scripts VMax dimming is controlled by a DMP 7000 or VIP 4400 4500 To adjust gamma navigate to the Configuration tab and click the Content sub tab...
Страница 48: ...the blue question mark button in the top left corner of the configuration utility screeen Refer to Figure 19 If further assistance is required Daktronics Customer Service is also available 24 7 via ph...
Страница 49: ...Daktronics Warranty Limitation of Liability 39 Appendix C Daktronics Warranty Limitation of Liability This section includes the Daktronics Warranty Limitation of Liability statement...
Страница 50: ......
Страница 51: ...upgraded or expedited transportation charges D Any replacement parts or Equipment will be new or serviceably used comparable in function and performance to the original part or Equipment and warrante...
Страница 52: ...of data loss resulting from system or service failure malfunction incompatitbility or breaches in system security or b any special consequential incidental or exemplary damages arising out of or in a...