– 34 –
Ethernet Control Port
The Ethernet port configuration is shown in
, and it controls settings for the
Ethernet port (J4). Once an option is set, an asterisk appears next to the entry, showing
that this value will be changed. All changes take effect immediately after exiting the
Ethernet Control Port menu. The controller may automatically reset to load the changes.
• Daktronics recommends setting the Baud Rate to Auto, but if communications are
failing, it may be set to Full or Half Duplex and 10 Mbps or 100 Mbps.
• Standard Protocol is TCP/IP and UDP/IP, but the controller can use a port server with a
serial TCP/IP protocol as well.
IP Settings
IP addresses and ports may be changed in the IP Settings menu; refer to
an option is set, the controller performs a soft reset.
Press the number of the field to change.
illustrates the Controller IP Address
menu. Then enter the IP address and press Enter to save.
Figure 77:
Ethernet Control Port
Figure 78:
IP Settings
Figure 79:
Controller IP Address