Installing and Configuring a DataProbe iBoot G2 for
Street Furniture
DD2594516 Rev 1
31 July 2013
PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128
tel: 800-325-8766 fax: 605-697-4700
www.daktronics.com
Action
Select From:
Selection
Action
None
AutoPing not used
Power On - Latch
Upon triggering, iBoot-G2+ will power on and remain so until changed vial the web, Telnet,
DxP, etc.
Power On - Follow Upon triggering, iBoot-G2+ will power on. When the ping response returns, iBoot-G2+ will
power off.
Power Off - Latch
Upon triggering, iBoot-G2+ will power off and remain so until changed via the web, Telnet,
DxP, etc.
Power Off - Follow Upon triggering, iBoot-G2+ will power off. When the ping response returns, iBoot-G2+ will
power on.
Power Cycle
Upon triggering, iBoot-G2+ will cycle the power. IBoot-G2+ will wait the Ping Frequency
x Fail Count: if the response does not return, the power will be recycled again. This will
continue until the ping response returns or Auto Ping is turned off. Make sure your Auto Ping
frequency is longer than the time required to reboot your device.
Power Cycle Once Upon triggering, iBoot-G2+ will cycle power one time. It will not cycle again automatically until
the ping response returns and is lost again.
With AutoPing operational, the main iBoot-G2+page will display the current status of this feature. The
status will be OK to indicate that iBoot-G2+ is receiving responses to the ping, or that the fail counter has
not been exceeded.
If the count failure has been exceeded, the status will change to FAIL. The Fail Counter will indicate the
number of times the failure has occurred, and the Trigger Counter indicates the number of times the
AutoPing action has been triggered. A counter reset button is provided when logging in with the Admin
password.
Note:
All of the AutoPing Settings require a reboot of the iBoot-G2+, after clicking Save. A Reboot
button will appear at the bottom of the page. The new settings will not take effect until the unit is
rebooted. Reboot will not affect the power position of the iBoot-G2+. Upon Clicking Reboot, the
Goodbye page is displayed with a link to re-login.
Passwords
Two passwords are used by
iBoot. The User Password allows
access to the control of the iBoot,
but not to the Setup function.
When this password is used,
the main screen will not have a
link to Setup. The Administrator
Password allows access to both
the Main Screen and the Setup
Figure 20: Password Settings
Содержание DAKT-0204-02
Страница 10: ...6 Cabinet Installation...
Страница 28: ...24 Maintenance Troubleshooting...
Страница 32: ......
Страница 34: ......
Страница 36: ......
Страница 41: ......
Страница 61: ......