Electrical Installation
13
Boot Sequence
The information in the boot sequence includes the following:
•
Firmware name & version
•
Display size (pixels high by pixels wide)
•
Dynamic Host Configuration Protocol (DHCP) assigned name
•
IP address & state
•
MAC address
•
Configuration port
•
Status port
•
Management port (used to access configuration)
•
Description
Startup Checklist
□
Confirm all communication equipment is installed according to the provided documentation.
□
Confirm any necessary network connections have been made.
□
Confirm the Venus® 1500 software is installed on the control computer.
□
Inspect the peripheral equipment (temperature sensor, light sensor, etc.) for proper installation.
Network & Communication Installation
This section explains the network settings of DSF-600 displays with the embedded controller and gives
basic guidance for integrating a display with a customer's network. It also provides basic information about
available standard communication options.
Daktronics is not responsible for setting up displays on a Wide Area Network (WAN) but does assist with
setting up communication on a Local Area Network (LAN) or directly to a laptop.
When installing network and communication:
•
Do not turn on the display until all network and communication installation is complete.
•
Have a laptop with Internet access on-site (preferred).
•
Work with a customer's IT professional for network integration (preferred).