Installing and Configuring a DataProbe iBoot G2 for
Street Furniture
DD2594516 Rev 1
31 July 2013
PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128
tel: 800-325-8766 fax: 605-697-4700
www.daktronics.com
Examples:
Use AutoPing as server monitor: iBoot-G2+ is installed with the device it monitors and automatically
reboots if there is no response. For street furniture, the player is a VIP.
Use Auto-Ping as service monitor: iBoot-G2+ is installed with the device to be rebooted, but pings a
remote host to test the communication channel. Ideal for: DSL 7 Cable Modem Verification.
iBoot-G2+ supports three independent AutoPing channels, each controlling either the Main power, or
either of the two Expansion ports. The first AutoPing channel can be programmed with two separate IP
Addresses with logical AND / OR comparison to determine the final action.
AutoPing Settings
IP Address
Enter the IP address of the device to be
pinged.
Ping Frequency
The Daktronics default is 300 seconds
but can range from 1 to 999 seconds.
The ping will go out to the selected
device this often.
Fail Count
The Daktronics default setting is eight
times but can range from 1-999 times
the ping needs to fail consecutively
before the selected action is taken.
When the fail count has been reached,
the AutoPing action will be triggered.
A/B Logic
(AutoPing 1 only) Select from A Only,
A AND B, A OR B. With and, both AutoPings need to exceed their fail count to trigger the Action. With
OR, the Action will be triggered if either AutoPing fails.
Control
Select Main for the inter power outlet, or Exp1, Exp2 for either of the two expansion ports.