SiUS12-928_B
Main Functions
Function and Control
46
1.10 HOME LEAVE Operation
Outline
FDXS-D Series
HOME LEAVE operation is a function that allows you to record your favorite set temperature and
airflow rate. You can start your favorite operation mode simply by pressing the [HOME LEAVE]
button on the remote controller.
Detail
1. Start of Function
The function starts when the [HOME LEAVE] button is pressed in cooling mode, heating mode
(including POWERFUL operation), or while the operation is stopped. If this button is pressed in
POWERFUL operation, the POWERFUL operation is canceled and this function becomes effective.
The [HOME LEAVE] button is ineffective in dry mode and fan mode.
2. Details of Function
A mark representing HOME LEAVE is indicated on the display of the remote controller. The indoor
unit is operated according to the set temperature and airflow rate for HOME LEAVE which were
pre-set in the memory of the remote controller.
The LED (red) of indoor unit representing HOME LEAVE lights up. (It goes out when the operation
is stopped.)
3. End of Function
The function ends when the [HOME LEAVE] button is pressed again during HOME LEAVE
operation or when the [POWERFUL] button is pressed.
Others
The set temperature and airflow rate are memorized in the remote controller. When the remote
controller is reset due to replacement of battery, it is necessary to set the temperature and airflow
rate again for HOME LEAVE operation.
<Cooling>
HOME LEAVE operation
Start
Stop
(R1366)
Time
Set temp.
Normal operation
“HOME LEAVE operation”
set temp.
Normal operation
<Heating>
(R1367)
Time
Set temp.
“HOME LEAVE operation”
set temp.
HOME LEAVE operation
Start
Stop
Normal operation
Normal operation
Содержание SUPER MULTI NX CDXS18LVJU
Страница 1: ...Service Manual G Series J Series SiUS12 928_B Applied Models Inverter Multi Heat Pump ...
Страница 9: ...SiUS12 928_B 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 15: ...SiUS12 928_B 7 Specifications Part 2 Specifications 1 Indoor Unit 8 2 Outdoor Unit 13 ...
Страница 118: ...SiUS12 928_B CTXS L FTXS L Series Operation Manual 110 3 12 Quick Reference Quick Reference C 3P297290 1 C 3P297290 2 ...
Страница 140: ...SiUS12 928_B CDXS L FDXS L Series Operation Manual 132 5 10 Quick Reference Quick Reference C 3P297290 3 ...