Service Check Function
SiUS12-928_B
141
Service Diagnosis
3.2
ARC433 Series Remote Controller
Check Method 1
1. When the timer cancel button is held down for 5 seconds,
00
is displayed on the temperature
display screen.
2. Press the timer cancel button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
Note:
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try the check
method 2. (
Refer to page 142.)
Timer cancel button
(R14555)
< ARC433 Series >
No.
Code
No.
Code
No.
Code
1
00
12
C7
23
H0
2
U4
13
H8
24
E1
3
F3
14
J3
25
P4
4
E6
15
A3
26
L3
5
L5
16
A1
27
L4
6
A6
17
C4
28
H6
7
E5
18
C5
29
H7
8
F6
19
H9
30
U2
9
C9
20
J6
31
UH
10
U0
21
UA
32
EA
11
E7
22
A5
33
AH
Содержание SUPER MULTI NX CDXS18LVJU
Страница 1: ...Service Manual G Series J Series SiUS12 928_B Applied Models Inverter Multi Heat Pump ...
Страница 9: ...SiUS12 928_B 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 15: ...SiUS12 928_B 7 Specifications Part 2 Specifications 1 Indoor Unit 8 2 Outdoor Unit 13 ...
Страница 118: ...SiUS12 928_B CTXS L FTXS L Series Operation Manual 110 3 12 Quick Reference Quick Reference C 3P297290 1 C 3P297290 2 ...
Страница 140: ...SiUS12 928_B CDXS L FDXS L Series Operation Manual 132 5 10 Quick Reference Quick Reference C 3P297290 3 ...