SiUS12-928_B
Field Settings
Trial Operation and Field Settings
266
Wireless Remote
Controller
(1) Remove the cover and take it off.
(2) Cut the address setting jumper.
5.2.4 Jumper Settings
For the location of the jumper, refer to the following pages.
CTXS/FTXS series: page 18, 20, 23
CDXS/FDXS series: page 26, 28
ARC452 series
ARC433 series
Jumper
ADDRESS
(R12065)
EXIST
CUT
1
2
Jumper
(R6573)
ADDRESS
EXIST
CUT
1
2
Jumper (on indoor
unit PCB)
Function
When connected
(factory set)
When cut
JB
Fan speed setting
when compressor
stops for thermostat
OFF. (effective only
at cooling operation)
Fan speed setting ;
Remote controller
setting
Fan speed setting; “0” (The fan
stops.)
JC
Power failure
recovery function
Auto-restart
The unit does not resume
operation after recovering from a
power failure. Timer settings are
cleared.
Содержание SUPER MULTI NX CDXS18LVJU
Страница 1: ...Service Manual G Series J Series SiUS12 928_B Applied Models Inverter Multi Heat Pump ...
Страница 9: ...SiUS12 928_B 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 15: ...SiUS12 928_B 7 Specifications Part 2 Specifications 1 Indoor Unit 8 2 Outdoor Unit 13 ...
Страница 118: ...SiUS12 928_B CTXS L FTXS L Series Operation Manual 110 3 12 Quick Reference Quick Reference C 3P297290 1 C 3P297290 2 ...
Страница 140: ...SiUS12 928_B CDXS L FDXS L Series Operation Manual 132 5 10 Quick Reference Quick Reference C 3P297290 3 ...