CTXS-L, FTXS-L Series
SiUS12-928_B
109
Operation Manual
29
Note for Multi System
COOL / HEAT mode lock
Priority room setting
Operation mode priority
[Example]
Priority when POWERFUL operation is used
[Example]
Priority when using OUTDOOR UNIT QUIET operation
[Example]
The priority room setting requires initial programming during installation. Please consult your authorized dealer for assistance.
The room designated as the priority room takes priority in the following situations.
The COOL / HEAT mode lock requires initial programming during installation. Please consult your authorized dealer for
assistance. The COOL / HEAT mode lock sets the unit forcibly to either COOL or HEAT operation. This function is convenient
when you wish to set all indoor units connected to the multi system to the same operation mode.
• As the operation mode of the priority room takes precedence, the user can select a different operation mode from other
rooms.
• Room A is the priority room in the examples.
When COOL operation is selected in room A while operating the following modes in room B, C and D :
Operation mode in room B, C and D
COOL or DRY or FAN
HEAT
AUTO
Status of room B, C and D when the unit in room A is in COOL operation
Current operation mode maintained
The unit enters standby mode. Operation resumes when the room A unit stops operating.
If the unit is set to COOL operation, it continues. If the unit is set to HEAT operation, it enters standby
mode. Operation resumes when the room A unit stops operating.
• Room A is the priority room in the examples.
The indoor units in rooms A, B, C and D are all operating. If the unit in room A enters POWERFUL operation, operation
capacity will be concentrated in room A. In such a case, the cooling (heating) efficiency of the units in room B, C and D may
be slightly reduced.
• Room A is the priority room in the examples.
Just by setting the unit in room A to QUIET operation, the air conditioner starts OUTDOOR UNIT QUIET operation.
You don’t have to set all the operated indoor units to QUIET operation.
Содержание SUPER MULTI NX CDXS18LVJU
Страница 1: ...Service Manual G Series J Series SiUS12 928_B Applied Models Inverter Multi Heat Pump ...
Страница 9: ...SiUS12 928_B 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 15: ...SiUS12 928_B 7 Specifications Part 2 Specifications 1 Indoor Unit 8 2 Outdoor Unit 13 ...
Страница 118: ...SiUS12 928_B CTXS L FTXS L Series Operation Manual 110 3 12 Quick Reference Quick Reference C 3P297290 1 C 3P297290 2 ...
Страница 140: ...SiUS12 928_B CDXS L FDXS L Series Operation Manual 132 5 10 Quick Reference Quick Reference C 3P297290 3 ...