3
x
Operation
Daikin RoCon HP
Daikin Control
008.1420844 – 05/2014
Operating instructions
15
Temporary timer programmes
For a specific situation there are 4
temporary programmes
available,
which
deactivate the permanent timer programmes
or the current operating mode for
the duration of their validity
.
The symbol of the temporary time program is displayed in the
header line of the standard display, as long as the time program
is active.
The following temporary time programmes may be
interrupted any time by manually changing the operat-
ing mode.
1.
[Party]:
Immediate one-off extension of the room
heating
a) If an automatic programme is activated, the last
applicable switching cycle is always extended. In the time
before switching cycle 1, the target room temperature set
in the parameter [T-Room 1 Setpoint] applies.
b) In all other operating modes, the target room temperature
set in the parameter [T-Room 1 Setpoint] applies.
– The hot water generation is not affected.
– The time programme runs for the set time period after acti-
vation.
2.
[Away]:
Immediate one-off setback
up to 6 hours
– The system operates in economy mode according to the
room temperature set in the rotary switch setting
"Set
Temp Night"
in the parameter [T-Absence].
– The hot water generation is not affected.
– The time programme runs for the set time period after acti-
vation.
3.
[Holiday]:
One-off calendar-controlled presence
.
– The system operates exclusively in accordance with the
"Sunday" settings in the [HC Program 1].
– The hot water generation operates exclusively in accord-
ance with the "Sunday" settings in the [DHW Program 1].
4.
[Vacation]:
One-off calendar-controlled setback
.
– The system only operates in economy mode according to
the room temperature set in the rotary switch setting
"Set
Temp Night"
in the parameter [T-Absence].
– Hot water generation according to the set temperatures
and switching cycles in the hot water time programme
[DHW Program 1] (see section 3.4.5).
– The calendar-controlled programme [Vacation] is
not
started
if the operating mode [Standby] or [Manual Oper-
ation] is active on the set start date.
3.4.8 System settings
We undertake the basic settings for the Control RoCon HP and
the system configurations for the installation environment of the
Daikin Altherma EHS(X/H), the direct heating circuit, the hot
water generation and any optionally connected components in
the rotary switch setting
"Configuration"
.
Depending on access authority (user or expert), various different
parameters are available. Certain parameters are only acces-
sible to the heating expert.
Setting the Language, Date, Time
An internal pre-programmed calendar ensures auto-
matic time reset at the annually recurring
summer/winter time changes. If required, the automatic
time changeover can be switched off.
●
Place the rotary switch in the
"Configuration"
position.
An overview is displayed.
●
Select the
"Setup"
level with the rotary switch.
An overview is displayed.
●
Use the rotary switch to select and confirm the [Language],
[Date] or [Time] parameters.
●
Select and change the value to be changed within the
individual display using the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in section 3.6 and in chapter 5.2.
3.4.9 Terminal function
In the rotary switch setting
"Remote Param"
, if terminal
mode is activated, other controllers in the RoCon system can also
be parameterised via the controller integrated in the CAN bus.
After activation of the "Bus - Scan" a list of the equipment that
was recognised is shown for selection in the display (external
equipment and local equipment).
After selection and acknowledgement of an external item of
equipment, this is shown on the local Control. The local control
element acts as the remote control for the external equipment. In
this case all the control functions are provided and saved 1:1 as
on the external equipment.
During this terminal function the header of the display carries ad-
ditional information on the remotely controlled equipment; the
symbol
#X indicates the bus ID setting for the remotely con-
trolled equipment.
The displayed values and symbols are always loaded from the
selected equipment (such as the mixer circuit infeed temperature
of the mixer module EHS157068).
Fig. 3-9
Display example for a remotely controlled mixer module
For operation of the local equipment, this must be activated again
in the selection list (parameter [No selection]).
If at the rotary switch setting
the message "n. A." is
displayed, the control unit has yet to be assigned a valid
terminal address.
If the message "n. A." is still displayed it may be nec-
essary to update the device software before the ter-
minal function can be used. Contact the Daikin Service
Team for this.