3
|
Components
Service manual
90
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
Prerequisite:
Remove the required plate work, see
151].
1
Disconnect the connector from the humidity sensor PCB.
2
Cut the tie strap that fixes the thermistor.
3
Carefully click the complete humidity sensor PCB assembly out of the indoor
unit.
a
b
a
Humidity sensor PCB assembly
b
Tie strap (thermistor fixation)
4
To install the humidity sensor PCB assembly, see
To install the humidity sensor
1
Click the humidity sensor PCB assembly on the indoor unit.
a
b
a
Humidity sensor PCB assembly
b
Tie strap (thermistor fixation)
2
Install the thermistor on the correct location and fix it to the bracket using a
new tie strap.
3
Connect the harness to the humicity sensor PCB assembly.
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.