3
|
Components
Service manual
122
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
3.11.2 Repair procedures
To remove the intelligent eye sensor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
151].
1
Remove the control panel from the indoor unit.
a
b
a
Control panel
b
Intelligent eye sensor PCB
2
Disconnect the connector from the intelligent eye sensor PCB.
3
Carefully click the complete intelligent eye sensor PCB out of the indoor unit.
4
To install the intelligent eye sensor PCB, see
To install the intelligent eye sensor
1
Click the intelligent eye sensor PCB on the indoor unit.
a
b
a
Control panel
b
Intelligent eye sensor PCB
2
Connect the harness to the intelligent eye sensor PCB.
3
Install the control panel on the indoor unit.
Is the problem solved?
Action
Yes
No further actions required.