3
|
Components
Service manual
74
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a
c
b
c
c
d
e
e
f
g
a
Screw (drain hose)
b
Drain hose
c
Screw (damper motor cover)
d
Damper motor cover
e
Screw (damper motor)
f
Damper motor
g
Damper motor wiring harness
3
Install the damper motor cover in the correct location on the indoor unit.
Make sure that the damper motor shaft is correctly inserted in the gear.
4
Install and tighten the 3 screw to fix damper motor covers.
5
Connect the drain hose to the indoor unit.
6
Install the drain hose fixation bracket. Install and tighten the screw.
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
To remove the damper motor wiring harness
Prerequisite:
73].
1
Remove the screw to disconnect the tie strap.
a
c
c
c
c
b
b
c
c
d
a
Screw (tie strap)
b
Damper motor wiring harness
c
Harness retainer
d
Damper motor connector on indoor unit main PCB
2
Route the damper motor wiring harness out of the harness retainers.