6
|
Technical data
Service manual
240
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
RXM50+60R + 60R
INFORMATION
The diagrams shown in this manual may be incorrect due to changes/updates to the
unit. Correct diagrams are supplied with the unit and can also be found in the
technical data book.
h
R2T
Y1E
e
c
a
b
d
j
S1PH
M1C
R3T
i
Y1S
R1T
M1F
f
g
i
i
M
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12.7· CuT
·12
.7·
CuT
·6.4· CuT
·9.
5·
CuT
·6.4· CuT
·6.
4·
CuT
·6.4· CuT
·6.4· CuT
·4.0· CuT
·4.0· CuT
·4.0· CuT
·9.
5·
CuT
·6.
4·
CuT
·9.5· CuT
·9.5· CuT
·12.7· CuT
a
Field piping (liquid: Ø6.4 mm flare connection)
M1C
Compressor
b
Field piping (gas: Ø12.7 mm flare connection)
M1F
Fan
c
Liquid stop valve
R1T
Thermistor (outdoor air)
d
Gas stop valve
R2T
Thermistor (heat exchanger)
e
Liquid receiver
R3T
Thermistor (discharge pipe)
f
Filter
S1PH
High pressure switch
g
Muffler with filter
Y1E
Electronic expansion valve
h
Heat exchanger
Y1S
4-way valve (ON: heating)
i
Muffler
Refrigerant flow: cooling
j
Accumulator
Refrigerant flow: heating