![Daikin MCK70ZVM-W Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/daikin/mck70zvm-w/mck70zvm-w_operation-manual_3280964044.webp)
43
Maintenance
Maintenance
Attention
Be sure to operate with the dust collection filter and deodorising filter attached.
If the unit is operated without the filters attached, malfunction may result.
Dust collection filter
Replace
Replace about every 10 years
About part replacement timing
• Replacement timing depends on usage patterns and the
location of the unit.
Standard replacement time is about 10 years assuming
that the unit is used daily in a home where 5 cigarettes
are smoked a day. (Calculation in accordance with testing
method of Japan Electrical Manufacturers’ Association
JEM1467 standard)
If the impurity content of the ambient air is high, the filter
will need more frequent replacement.
If the filter is failing to perform, it is time to replace it.
About purchasing and disposal
¼
Refer to “Separately Sold Parts”.
►
Page 56
1.
Remove the water tank.
►
Page 17
2.
Remove the humidifying tray.
►
Page 15
3.
Remove the filter fixing unit.
►
Page 15
4.
Remove the deodorising filter.
Hold the side of the filter and remove it.
Deodorising filter
5.
Remove the dust collection filter.
1
Pull the filter tag upward.
2
Hold the lower part of the dust collection filter and
lift it out.
Dust collection filter
6.
Attach a new dust collection filter.
•
If it is hard to install, push the dust collection filter
while installing.
Side with tag and
markings should face
toward you and arrow
should point up
7.
Attach the deodorising filter.
►
Page 15
8.
Attach the filter fixing unit.
►
Page 15
9.
Attach the humidifying tray.
►
Page 39
10.
Put the water tank in.
►
Page 17
01_EN_3P693798-1B.indd 43