![Daikin MCK70ZVM-W Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/daikin/mck70zvm-w/mck70zvm-w_operation-manual_3280964026.webp)
25
Operation
Operation
MODE
Usage and Function
AUTO FAN
Automatic airflow rate adjustment
FAN setting (“Quiet”, “Low”, “Standard”, “High*”) is automatically adjusted according to the degree
of air impurity and humidity (when the Humidifying operation is active).
Purifying capacity increases as airflow rate rises.
If the operating sound bothers you, the airflow rate range can be changed.
►
Page 31, 32
* The maximum airflow rate during AUTO FAN MODE is “High”, which is less powerful than “Turbo”.
• Press
if you want to change the humidity level.
• Degree of air impurity corresponds to the volume of dust and the intensity of odours in the ambient air.
ECONO
Saving energy
In Power saving mode within ECONO MODE, the FAN setting automatically switches between
“Quiet” and “Low” only. Power consumption (*1) and operating sounds are reduced.
If the air is clean and the set humidity level has been achieved (when the Humidifying operation is
active), after about 5 minutes passes, Monitoring mode automatically activates. Recommended for
use during sleep hours.
*1 By comparison to AUTO FAN MODE (about 15.4Wh), power consumption in ECONO MODE (about
8.4Wh) is about 7.0Wh lower.
Test conditions case in Japan: operation in 10m² area over 1 hour. Assuming 1 cigarette was smoked
immediately after the unit was turned on.
OFF
OFF
OFF
Streamer
Humidification
Active plasma ion
(*2)
Power saving mode
If the air is clean and the set
humidity has been reached
for about 5 minutes...
Monitoring mode
•
The fan starts and stops periodically, and
dust, odour and humidity is checked.
•
Turn “Off” the following functions to further
reduce power consumption.
If the humidity level falls, or
dust or odours are
detected...
The unit operates
automatically with an
airflow rate of “Quiet”
and “Low”.
*2 The humidifier lamp remains lit.
•
Air purification and humidification capacity will be reduced as only “Quiet” and “Low” operation are used.
• Since the air in the room is not drawn in while the fan is stopped, the sensitivity of the PM2.5 sensor,
odour sensor, and humidity sensor will decrease. If you do not want the sensitivity of the sensors to be
reduced, set Monitoring mode to “OFF”.
►
Page 31, 32
• Press
if you want to change the humidity level.
01_EN_3P693798-1B.indd 25
2023/06/26 13:34:03
Содержание MCK70ZVM-W
Страница 114: ...57 MEMO 02_TR_3P693798 1B indd 57 2023 06 26 13 39 11...