10
English
Read First
AIR MONITOR indicator (white) (rough estimate)
Indicates what setting is selected with
to display. (Settings at time of purchase : μg/m
3
)
•
μg/m
3
(PM2.5 concentration)
Displays the concentration of PM2.5 in the room in the range of 0 to 99μg/m
3
. (Steps of 1μg/m
3
)
If the concentration exceeds 99μg/m
3
, “HI” is displayed.
• [
--
] is displayed for about 1 minute immediately after operation start regardless of the PM2.5 concentration.
•
°C (current indoor temperature)
Displays the current room temperature in the range of 0°C to 39°C. (Steps of 1°C)
When the temperature is below 0°C, “0” is displayed. When the temperature is above 39°C, “39” is displayed.
• [
--
] is displayed for about 30 seconds immediately after operation start regardless of the indoor temperature.
• % (current indoor humidity)
Displays the room humidity in the range of 20% to 90%. (Steps of 1%)
When the humidity level is below 20%, “20” is displayed. When the humidity level is above 90%, “90” is displayed.
• The indicator will light up even when only the air purifying operation is active.
• [
--
] is displayed for about 30 seconds immediately after operation start regardless of the indoor humidity.
The display on the unit may
differ from that of the other
hygrometers or
thermometers.
• This is because the humidity,
temperature and the volume
of PM2.5 become uneven
even in the same room due
to the flow of air. Please use
the Air monitor indicator as a
rough estimate.
States of the Air monitor
indicator and their meanings
►
Page 47
Odour sensor lamp
Indicates the intensity of odours in 3 colours: blue, orange, red.
• Blue indicates that the air is clean.
Blue
Orange
Red
Low
High
Lamp
colour
Odours
If operation is started immediately after the power
supply plug is inserted, the lamp will light blue for
about the first 1 minute.
If odour intensity levels are unchanging, the sensor may
not respond even if there is a strong odour in the air.
The following types of odours may not be detected: pet
odours that do not include ammonia, garlic odours, etc.
As odour perception varies by person, in some cases an
odour may be sensed even when the lamp is blue.
If the odour bothers you, switch to manual airflow rate, and
select a high airflow rate.
►
Page 22
The basic sensitivity of the odour sensor will be determined by odour
levels in the about the first 1 minute after the power supply plug is
inserted. Insert the power supply plug when the air is clean (odour-free).
Odour sensor detection range
Detectable matter
tobacco odours, cooking odours, pet odours, toilet smells,
waste smells, mould odour, sprays, alcohol
Sometimes detectable
sudden changes in temperature/humidity, steam, oil smoke,
gas emitted from combustion-based heating devices
01_EN_3P693798-1B.indd 10
2023/06/26 13:33:57