background image

FXDQ-SPV1 EDTFVN391825

27

3P347455-11H

2

2-3 Optional parts

   (b) Places in which corrosive gas can be generated, such 

         as sulfur dioxide.

         The copper pipes or welded parts can be corroded 

         and lead to refrigerant leakage.

   (c) Places near any machine which generates 

         electromagnetic wave.

         Electromagnetic wave can have influence on the 

         control system, so the air conditioner cannot work 

         properly.

   (d) Places in which any combustible gas is leaked out, any 

         carbon fiber or combustible powder floats, or volatile 

         combustible gas such as gasoline or thinner is stored.

         In case that the air conditioner is used in such places, 

         fire can occur.

· 

Please never touch any fin of the heat exchanger.

   Improper touching can cause damages.

· 

Please pay special attention to the transport of the product.

   PP packing straps are used for some products. Please 

   never lift and pull the PP packing straps to transport. 

   It is dangerous.

· 

For the sake of safety, please discard the packing materials.

   Packing materials such as nails and timbers can lead to 

   stabbings or other harms. 

   Please tear off and discard the plastic bags, so as to 

   prevent children from playing with plastic bags and leading 

   to suffocation.

· 

Please do not switch off the power supply when the 

   operation is just stopped.

   Please wait for at least 5 minutes before switching off the 

   power supply.

   Otherwise water leakage and other problems can occur.

· 

Depending on different setting environment, electromagnetic 

   interference can occur for different products.

   In this case, keep proper distance from the product.

Please follow the State standards to carry out the 

installation work.

2. BEFORE INSTALLATION

Before the installation work is completed, please 

never discard any accessory which may be required 

during installation. Never discard!

1. Determine the route for moving in the air conditioner 

    in advance.

2. Before moving the air conditioner to the place of 

    installation, never unpack it. In cases that the air 

    conditioner has to be unpacked, soft ropes shall be 

    used when hoisted up or a protection plate shall be 

    placed in the point of the hoisting cable, so as to 

    prevent the air conditioner from damage or scratching.

When moving the air conditioner whether when it is 

being unpacked or after it is unpacked, please hold 

the hoisting bracket base. Never apply force on the 

refrigerant pipe, water drainage pipe or plastic parts.

Before installing the air conditioner, please confirm 

whether the refrigerant used is R410A refrigerant.

For the installation of the outdoor unit, please make 

references to the installation manual for the outdoor unit.

2-1 Notes

· 

Please tell the correct operating methods of the various 

   functions as well as the temperature adjustment 

   methods of the air conditioner to the user, and ask the 

   user to read the operation manual and carry out 

   operations at the same time.

· 

The air conditioner is not suitable to be installed in 

   places in which high content of salt is contained in the air, 

   such as coast; and is not suitable in places in which the 

   fluctuation of voltage is high, such as factory.

   The air conditioner is also not suitable to be used in 

   vehicles or ships.

2-2 Accessories

Please check whether the following articles are supplied 

with the air conditioner.

Name

Metal clip (1)

Water drainage 

hose (2)

Insulation piece 

for connector

Seal

Quantity

1 piece

1 piece

1 piece each

1 piece each

Shape

For liquid pipe (3)

Large (5)

For air pipe (4)

Middle (6)

Name

Bolt for flange 

connection (7)

Washer for hoisting

bracket base (8)

Banding tie

Quantity

1 set

8 pieces

1 set

Shape

Large (9)

8 pieces

16 pieces

Small (10)

4 pieces

Name

Quantity

Shape

Washer positioning

 plate (11)

Seal (12)

4 pieces

2 pieces

(Other)
•  Operation manual
•  Installation manual
•  Conforming certificate 

   of product

· 

The indoor unit needs one remote control for operations 

   as listed in the following table.

Remote control

Applicable model

Wired R/C

Wireless 

R/C

H/P

C/O

BRC1C62 (3 ranges)

FXDQ 

~ 

SPV1

a. Key points to be inspected after completion of 

    installation.

During installation work and during inspection after 

completion of installation, pay special attention to 

the following points.

Items of Inspection

Are the indoor unit and outdoor 

unit installed firmly?
Has air leakage inspection been 

carried out?

Is the heat insulation good? 

(Refrigerant pipe, water 

drainage pipe and air pipe)
Is water smoothly drained off?
Is the power voltage consistent 

with the one specified on the 

nameplate of the machine?
Is the connection of the cable 

and the pipe correct?
Is the air conditioner safely 

grounded?
Are cables with the specified 

specifications used?
Are the suction inlet and air 

blow outlet of the indoor unit 

and the outdoor unit blocked by 

anything?
Have the length of the refrigerant 

pipe and the filled amount of 

refrigerant been recorded?

Results possibly occurring 

in case of any error

Inspected 

and signature

At the same time, please make references to Section 

“SAFETY PRECAUTIONS”.

The air conditioner falls off, 

vibrates and sends out noise.
There is no sufficient cool air 

or hot air.

Condensate drips off.

Water leaks out.

The machine cannot work 

normally or parts are burnt off.
The machine cannot work 

normally or parts are burnt off.
Once there is electricity 

leakage, it is very dangerous.
The machine cannot work 

normally or parts are burnt off.

There is no sufficient cool air 

or hot air.

The amount of the refrigerant 

of the air conditioning system 

is unknown.

BRC1E62 (3 ranges)
BRC4C65 (3 ranges)
BRC4C66 (3 ranges)

Содержание FXDQ-SPV1

Страница 1: ...FXDQ SPV1 EDTFVN391825 201803 Engineering Data 50 Hz...

Страница 2: ......

Страница 3: ...ams 10 6 Electric Characteristics 11 7 Safety Devices Setting 12 8 Capacity Tables 13 8 1 Cooling Capacity for Te Auto 13 8 2 Cooling Capacity for Te 6 C 13 8 3 Cooling Capacity for Te 9 C 14 8 4 Heat...

Страница 4: ...5 2 1 Lineup Capacity range 2 2 kW 2 8 kW 3 6 kW 4 5 kW 5 6 kW 7 1 kW 0 8 HP 1 HP 1 25 HP 1 6 HP 2 HP 2 5 HP Capacity index 20 25 31 25 40 50 62 5 FXDQ 20SPV1 25SPV1 32SPV1 40SPV1 50SPV1 63SPV1 V1 1 p...

Страница 5: ...tion manual Drain hose Sealing pads Clamps Washers Insulation for fitting Metal clamp Washer fixing plate Screws for duct flanges Operation manual Installation manual Drain hose Sealing pads Clamps Wa...

Страница 6: ...manual Drain hose Sealing pads Clamps Washers Insulation for fitting Metal clamp Washer fixing plate Screws for duct flanges Operation manual Installation manual Drain hose Sealing pads Clamps Washers...

Страница 7: ...on manual Drain hose Sealing pads Clamps Washers Insulation for fitting Metal clamp Washer fixing plate Screws for duct flanges Operation manual Installation manual Drain hose Sealing pads Clamps Wash...

Страница 8: ...FXDQ SPV1 EDTFVN391825 6 3 Dimensions FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 3D071829D Unit mm...

Страница 9: ...FXDQ SPV1 EDTFVN391825 7 FXDQ40SPV1 FXDQ50SPV1 3D071831D Unit mm...

Страница 10: ...FXDQ SPV1 EDTFVN391825 8 FXDQ63SPV1 3D071830D Unit mm...

Страница 11: ...iagrams FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1 Refrigerant pipe connection port diameters Unit mm Model Gas Liquid FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 12...

Страница 12: ...FXDQ SPV1 EDTFVN391825 10 5 Wiring Diagrams FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1 3D099151...

Страница 13: ...FXDQ SPV1 EDTFVN391825 11 6 Electric Characteristics FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1 4D090515...

Страница 14: ...50 V 5 A Fan motor thermal fuse C Fan motor thermal protector C OFF 130 5 ON 83 15 OFF 130 5 ON 83 15 OFF 130 5 ON 83 15 Model FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1 Printed circuit board fuse A1P 250 V 5 A...

Страница 15: ...gth Please confirm that the corrected capacity of the VRV system satisfies the required heat load 2 shows rated condition 8 2 Cooling Capacity for Te 6 C Model Capacity indication Indoor air temp 14 C...

Страница 16: ...These capacity tables are for use when selecting a VRV indoor unit The actual capacity of the VRV system depends on factors such as the selected model of outdoor units outdoor air temperature and pip...

Страница 17: ...FXDQ SPV1 EDTFVN391825 15 9 Fan Performances FXDQ20SPV1 3D072697C...

Страница 18: ...FXDQ SPV1 EDTFVN391825 16 FXDQ25SPV1 3D072698C...

Страница 19: ...FXDQ SPV1 EDTFVN391825 17 FXDQ32SPV1 3D090527...

Страница 20: ...FXDQ SPV1 EDTFVN391825 18 FXDQ40SPV1 FXDQ50SPV1 3D072702C...

Страница 21: ...FXDQ SPV1 EDTFVN391825 19 FXDQ63SPV1 3D090542...

Страница 22: ...FXDQ SPV1 EDTFVN391825 20 10 Sound Levels FXDQ20SPV1 FXDQ25SPV1 4D090507A 4D090508A...

Страница 23: ...FXDQ SPV1 EDTFVN391825 21 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 4D090509A 4D090510A...

Страница 24: ...FXDQ SPV1 EDTFVN391825 22 FXDQ63SPV1 4D090511A...

Страница 25: ...FXDQ SPV1 EDTFVN391825 23 11 Centre of Gravity FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 4D072718G Unit mm 4D072719G Unit mm...

Страница 26: ...FXDQ SPV1 EDTFVN391825 24 FXDQ63SPV1 4D072720H Unit mm...

Страница 27: ...s Item Model FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1 Remote controller Wireless Cooling Only BRC4C66 Heat Pump BRC4C65 Wired BRC1C62 Navigation remote controller Wired remote...

Страница 28: ...ctrical shock or fire Use cables with the specified specifications and all the cables shall be reliably connected and the wiring terminals and the cables are not tensioned by any external force Poor w...

Страница 29: ...ting methods of the various functions as well as the temperature adjustment methods of the air conditioner to the user and ask the user to read the operation manual and carry out operations at the sam...

Страница 30: ...y drained off The strength of the ceiling can withstand the weight of the indoor unit The ceiling is not obviously tilted There is no hazard of possible leakage of combustible gas There is enough spac...

Страница 31: ...an be built in the new ceiling and other items purchased in the market can be used Please refer to Fig 3 Fig 3 Top ceiling Pile anchor screw Long nut or screw thread device Hoisting bolt Note The leng...

Страница 32: ...r air exchange 1 Connect the pipe Refrigerant has been filled in the outdoor unit Align the connecting section of the refrigerant pipe to the center of the flare section and firstly turn 3 4 operation...

Страница 33: ...pipe of the air supply side The flare nut section The pipe supplied on site must be heat insulated to the connecting section of the pipe In case that the pipe is exposed condensate can occur and inju...

Страница 34: ...ng band Water drainage hose 2 Large seal 5 Accessory Metal clip 1 Accessory 4mm Precautions on installing the water drainage riser pipe Case for Model FXDQ SPV1 Please confirm that the height of the w...

Страница 35: ...e air conditioner Point 12 14 or 16 Use sealing materials such as aluminum adhesive tape to seal the connection section between the flange and the air pipe on the air inlet side so as to prevent air l...

Страница 36: ...is within a place easily in contact with people please install an electricity leakage circuit breaker to prevent electrical shock 4 When an electricity leakage circuit breaker is used please use a dev...

Страница 37: ...ng cable to the electrical box When connecting the cables the cables shall be routed orderly and placed even and the electrical box cover shall not be supported up and the electrical box cover shall b...

Страница 38: ...auses as loosened cables When connected to the terminal board please use round wiring terminal with insulated sleeve In case that round wiring terminal with insulated sleeve cannot be used connect the...

Страница 39: ...Electrical Wiring Work 3 Remove the electrical box cover 4 Connect remote control 2 Slave to the terminal board of the remote control cable in the electrical box P1 and P2 No polarity 1 P 2 P 1 F 2 F...

Страница 40: ...Setting the time to display the clean air filter element signal To change the Setting for contamination level of the air filter element tell the following contents to the user The factory setting to d...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ...rts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of...

Отзывы: