Code
Description
[7.4.3.2]
[6-0B]
30°C~min(50, [6‑0E])°C
Reheat
The desired reheat tank temperature is used:
▪
in reheat mode of scheduled + reheat mode: The guaranteed minimum tank
temperature is set by T
HP OFF
–[6‑08], which is either [6‑0C] or the weather-
dependent setpoint, minus the reheat hysteresis. If the tank temperature drops
below this value, the tank is heated up.
#
Code
Description
[7.4.3.3]
[6-0C]
30°C~min(50, [6‑0E])°C
Reheat hysteresis
Only applicable when domestic hot water preparation is sch reheat.
#
Code
Description
N/A
[6-08]
2°C~20°C
Weather dependent
The weather dependent installer settings define the parameters for the weather
dependent operation of the unit. When weather dependent operation is active the
desired tank temperature is determined automatically depending on the averaged
outdoor temperature: low outdoor temperatures will result in higher desired tank
temperatures as the cold water tap is colder and vice versa. In case of scheduled or
screheat domestic hot water preparation, the storage comfort
temperature is weather dependent (according to the weather dependent curve),
the storage economic and reheat temperature are NOT weather dependent. In
case of reheat only domestic hot water preparation, the desired tank temperature
is weather dependent (according to the weather dependent curve). During
weather dependent operation, the end-user cannot adjust the desired tank
temperature on the user interface.
#
Code
Description
[A.4.6]
N/A
Desired temperature mode:
▪
Fixed
: disabled. All desired tank temperature
are NOT weather dependent.
▪
Weather dep.
: enabled. In scheduled or
screheat mode, the storage comfort
temperature is weather dependent. Storage
economic and reheat temperatures are NOT
weather dependent. In reheat mode, the
desired
tank
temperature
is
weather
dependent.
Note:
When the displayed tank temperature is
weather dependent, it cannot be adjusted on
the user interface.
Содержание ERLA03DAV3
Страница 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Страница 182: ...1 7 Field settings table 6 8 2 ID9E51 Applicable units EHFZ03S18DJ3V Notes 4P596829 1 2019 10...
Страница 189: ......
Страница 190: ......
Страница 191: ......
Страница 192: ...4P596821 1A 2020 05 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...