5/7
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[3-00]
R/W
0: No
1: Yes
A.8
[3-01]
0
A.8
[3-02]
1
A.8
[3-03]
4
A.8
[3-04]
2
A.8
[3-05]
1
A.8
[3-06]
R/W
18~30°C, step: 0,5°C
30°C
A.8
[3-07]
R/W
12~18°C, step: 0,5°C
12°C
A.8
[3-08]
R/W
25~35°C, step: 0,5°C
35°C
A.8
[3-09]
R/W
15~25°C, step: 0,5°C
15°C
A.8
[4-00]
R/W
0: Disabled
1: Enabled
2: Only DHW
A.8
[4-01]
R/W
0: None
1:
-
2: BUH
A.8
[4-02]
R/W
14~35°C, step: 1°C
22°C
A.8
[4-03]
3
A.8
[4-04]
R/O
0: intermittent pump operation
1: Continuous pump operation
2: OFF
A.8
[4-05]
0
A.8
[4-06]
R/W
0: Manual
1: Automatic
A.8
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
A.8
[4-09]
R/W
0: Current
1: Power
A.8
[4-0A]
0
A.8
[4-0B]
R/W
1~10°C, step: 0,5°C
1°C
A.8
[4-0D]
R/W
1~10°C, step: 0,5°C
3°C
A.8
[5-00]
R/W
0: Allowed
1: Not allowed
A.8
[5-01]
R/W
-15~35°C, step: 1°C
0°C
A.8
[5-02]
R/W
0: Disabled
1: Enabled
A.8
[5-03]
R/W
-15~35°C, step: 1°C
0°C
A.8
[5-04]
R/W
0~20°C, step: 1°C
10°C
A.8
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-06]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-07]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-08]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0A]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0B]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0C]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0D]
0
A.8
[5-0E]
1
A.8
[6-00]
R/W
2~40°C, step: 1°C
25°C
A.8
[6-01]
R/W
0~10°C, step: 1°C
2°C
A.8
[6-02]
0
A.8
[6-03]
0
A.8
[6-04]
0
A.8
[6-05]
0
A.8
[6-06]
0
A.8
[6-07]
0
A.8
[6-08]
R/W
2~20°C, step: 1°C
10°C
A.8
[6-09]
0
A.8
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
A.8
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
A.8
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
A.8
[6-0E]
R/W
40~60°C, step: 1°C
60°C
A.8
[7-00]
0
A.8
[7-01]
2
A.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.8
[7-03]
2.5
A.8
[7-04]
0
A.8
[7-05]
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
A.8
[8-00]
R/W
0~20 min, step 1 min
1 min
A.8
[8-01]
R/W
5~95 min, step: 5 min
30 min
Is the pump allowed during pipe freeze prevention?
Minimum running time for domestic hot water operation.
Maximum running time for domestic hot water operation.
--
--
How many leaving water temperature zones are there?
--
--
Boiler efficiency
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
What is the maximum temperature setpoint?
--
--
--
--
--
What is the hysteresis to be used in reheat mode?
What is the requested limit for DI4?
--
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
--
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
What is the equilibrium temperature for the building?
Space heating priority.
Space heating priority temperature.
Set point correction for domestic hot water temperature.
What is the requested limit for DI1?
Emergency
Which power limitation mode is required on the system?
Which power limitation type is required?
--
Automatic cooling/heating changeover hysteresis. (*)
Automatic cooling/heating changeover offset. (*)
What is the minimum desired room temperature in cooling? (*)
What is the BUH operation mode?
Which electric heater has priority?
Below which outdoor temperature is heating allowed?
--
--
--
--
--
What is the maximum desired room temperature in heating?
What is the mimimum desired room temperature in heating?
What is the maximum desired room temperature in cooling? (*)
Is auto restart of the unit allowed?
--
--
(*) Setting is not applicable for this unit
4P4596829-1 - 2019.10
Содержание ERLA03DAV3
Страница 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Страница 182: ...1 7 Field settings table 6 8 2 ID9E51 Applicable units EHFZ03S18DJ3V Notes 4P596829 1 2019 10...
Страница 189: ......
Страница 190: ......
Страница 191: ......
Страница 192: ...4P596821 1A 2020 05 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...