4/7
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.6.3.4
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
└─
Averaging time
A.6.4
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─
Ext amb. sensor offset
A.6.5
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
└─
Emergency
A.6.C
R/W
0: Manual
1: Automatic
└─
Disable protective Function
A.6.D
Disable protections
R/W
0: No
1: Yes
└─
Overview settings
A.8
[0-00]
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
A.8
[0-01]
R/W
[9-05]~[9-06]°C, step: 1°C
50°C
A.8
[0-02]
R/W
10~25°C, step: 1°C
15°C
A.8
[0-03]
R/W
-40~5°C, step: 1°C
-10°C
A.8
[0-04]
R/W
[9-07]~[9-08]°C, step: 1°C
8°C
A.8
[0-05]
R/W
[9-07]~[9-08]°C, step: 1°C
12°C
A.8
[0-06]
R/W
25~43°C, step: 1°C
35°C
A.8
[0-07]
R/W
10~25°C, step: 1°C
20°C
A.8
[0-0B]
R/W
35~[6-0E]°C, step: 1°C
55°C
A.8
[0-0C]
R/W
45~[6-0E]°C, step: 1°C
60°C
A.8
[0-0D]
R/W
10~25°C, step: 1°C
15°C
A.8
[0-0E]
R/W
-40~5°C, step: 1°C
-10°C
A.8
[1-00]
R/W
-40~5°C, step: 1°C
-10°C
A.8
[1-01]
R/W
10~25°C, step: 1°C
15°C
A.8
[1-02]
R/W
[9-01]~[9-00], step: 1°C
35°C
A.8
[1-03]
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
A.8
[1-04]
R/W
0: Disabled
1: Enabled
A.8
[1-05]
R/W
0: Disabled
1: Enabled
A.8
[1-06]
R/W
10~25°C, step: 1°C
20°C
A.8
[1-07]
R/W
25~43°C, step: 1°C
35°C
A.8
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
A.8
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
A.8
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
A.8
[1-0B]
R/W
3~66°C, step: 1°C
5°C
A.8
[1-0C]
R/W
3~10°C, step: 1°C
5°C
A.8
[1-0D]
R/W
3~10°C, step: 1°C
5°C
A.8
[1-0E]
R/W
3~10°C, step: 1°C
5°C
A.8
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
A.8
[2-01]
R/W
0: No
1: Yes
A.8
[2-02]
R/W
0~23 hour, step: 1 hour
1
A.8
[2-03]
R/W
60°C
A.8
[2-04]
R/W
40~60 min, step: 5 min
40 min
A.8
[2-05]
R/W
4~16°C, step: 1°C
12°C
A.8
[2-06]
R/W
0: Disabled
1: Enabled
A.8
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
A.8
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
A.8
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
A.8
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
A.8
[2-0D]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
kW value
What is the required offset on the measured outdoor temp.?
What emitter type is connected to the main LWT zone
What emitter type is connected to the additional LWT zone?
What is the disinfection target temperature?
How long must the tank temperature be maintained?
Room antifrost temperature
Room frost protection
Adjust the offset on the measured room temperature
Adjust the offset on the measured room temperature
What is the desired delta T in heating for the additional zone?
What is the desired delta T in cooling for the main zone? (*)
What is the desired delta T in cooling for the additional zone? (*)
When should the disinfection function be executed?
Should the disinfection function be executed?
When should the disinfection function start?
Low ambient temp. for LWT main zone cooling WD curve. (*)
High ambient temp. for LWT main zone cooling WD curve. (*)
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
(*)
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
(*)
What is the averaging time for the outdoor temp?
What is target delta T in heating?
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Weather dependent cooling of the main leaving water temperature zone. (*)
Weather dependent cooling of the additional leaving water temperature zone (*)
High ambient temp. for LWT add zone cooling WD curve. (*)
Low ambient temp. for LWT add zone cooling WD curve. (*)
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
(*)
Leaving water value for low ambient temp. for LWT add zone cooling WD curve. (*)
4P596829-1 - 2019.10
(*) Setting is not applicable for this unit
Содержание ERLA03DAV3
Страница 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Страница 182: ...1 7 Field settings table 6 8 2 ID9E51 Applicable units EHFZ03S18DJ3V Notes 4P596829 1 2019 10...
Страница 189: ......
Страница 190: ......
Страница 191: ......
Страница 192: ...4P596821 1A 2020 05 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...