2 About the box
Installation manual
4
EHYHBH05AAV3* + EHYHBH/X08AAV3*
Daikin Altherma hybrid heat pump – heat pump module
4P349587-1F – 2016.10
2
About the box
2.1
Indoor unit
2.1.1
To unpack the indoor unit
a
b
a
Installation manual, operation manual, addendum book for
optional equipment, quick installation guide, general safety
precautions, boiler communication cable
b
Connection pieces for the gas boiler
INFORMATION
Do NOT throw away the upper cardboard cover. On the
outside of the cardboard cover, the installation pattern is
printed.
2.1.2
To remove the accessories from the
indoor unit
The installation manual, operation manual, addendum book for
optional equipment, general safety precautions, quick installation
guide, and boiler communication cable are located in the upper part
of the box. The connection pieces for the gas boiler are attached to
the water piping.
1
Remove the accessories as described in
"2.1.1 To unpack the
indoor unit" on page 4
.
a
b
c
d
e
f
g
a
General safety precautions
b
Addendum book for optional equipment
c
Indoor unit installation manual
d
Operation manual
e
Quick installation guide
f
Connection pieces for gas boiler
g
Boiler communication cable
3
Preparation
3.1
Preparing installation site
3.1.1
Installation site requirements of the
indoor unit
▪ Mind the following spacing installation guidelines:
>500
300
300
10
350
500
(mm)
▪ The indoor unit is designed for indoor installation only and for
ambient temperatures ranging 5~35°C in cooling mode and
5~30°C in heating mode.
3.2
Preparing water piping
NOTICE
In case of plastic pipes, make sure they are fully oxygen
diffusion tight according to DIN 4726. The diffusion of
oxygen into the piping can lead to excessive corrosion.