4 Installation
Installation manual
5
EHYHBH05AAV3* + EHYHBH/X08AAV3*
Daikin Altherma hybrid heat pump – heat pump module
4P349587-1F – 2016.10
3.2.1
To check the water volume and flow rate
Minimum water volume
Check that the total water volume in the installation is minimum
13.5 litre, the internal water volume of the indoor unit NOT included.
INFORMATION
In critical processes, or in rooms with a high heat load,
extra water might be required.
NOTICE
When circulation in each space heating loop is controlled
by remotely controlled valves, it is important that the
minimum water volume is guaranteed, even if all of the
valves are closed.
Minimum water volume
Check that the total water volume in the installation is minimum
13.5 litre, the internal water volume of the indoor unit NOT included.
INFORMATION
In critical processes, or in rooms with a high heat load,
extra water might be required.
NOTICE
When circulation in each space heating loop is controlled
by remotely controlled valves, it is important that the
minimum water volume is guaranteed, even if all of the
valves are closed.
Minimum flow rate
Check that the minimum flow rate (required during defrost/backup
heater operation) in the installation is guaranteed in all conditions.
NOTICE
When circulation in each or certain space heating loops is
controlled by remotely controlled valves, it is important that
the minimum flow rate is guaranteed, even if all valves are
closed. In case the minimum flow rate cannot be reached,
a flow error 7H will be generated (no heating/operation).
See the installer reference guide for more information.
Minimum required flow rate
05 models
7 l/min
08 models
8 l/min
See the recommended procedure as described in
"6.2 Checklist
during commissioning" on page 20
.
3.3
Preparing electrical wiring
3.3.1
Overview of electrical connections for
external and internal actuators
Item
Description
Wires
Maximum
running
current
Outdoor unit and indoor unit power supply
1
Power supply for
outdoor unit
2+GND
(a)
2
Power supply and
interconnection cable to
indoor unit
3+GND
(g)
3
Power supply gas
boiler
2+GND
(c)
Item
Description
Wires
Maximum
running
current
4
Preferential kWh rate
power supply (voltage
free contact)
2
(e)
5
Normal kWh rate power
supply
2
6.3 A
User interface
6
User interface
2
(f)
Optional equipment
7
3‑way valve
3
100 mA
(b)
8
Domestic hot water
tank thermistor
2
(d)
9
Power supply for drain
pan heater
2
(b)
10
Room thermostat/heat
pump convector
3 or 4
100 mA
(b)
11
Outdoor ambient
temperature sensor
2
(b)
12
Indoor ambient
temperature sensor
2
(b)
Field supplied components
13
Shut-off valve
2
100 mA
(b)
14
Electricity meter
2
(b)
15
Domestic hot water
pump
2
(b)
16
Alarm output
2
(b)
17
Changeover to external
heat source control
2
(b)
18
Space cool/heat
operation control
2
(b)
19
Power consumption
digital inputs
2 (per input
signal)
(b)
20
Gas meter
2
(b)
21
Safety thermostat
2
(e)
(a)
Refer to name plate on outdoor unit.
(b)
Minimum cable section 0.75 mm².
(c)
Use the cable supplied with the boiler.
(d)
The thermistor and connection wire (12 m) are delivered
with the domestic hot water tank.
(e)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
50 m. Voltage-free contact shall ensure the minimum
applicable load of 15 V DC, 10 mA.
(f)
Cable section 0.75 mm² till 1.25 mm²; maximum length:
500 m. Applicable for both single user interface and dual
user interface connection.
(g)
Cable section 1.5 mm
2
; maximum length: 50 m.
NOTICE
More technical specifications of the different connections
are indicated on the inside of the indoor unit.
4
Installation
4.1
Opening the units
4.1.1
To open the switch box cover of the
indoor unit
1
Remove the side panel at the right side of the indoor unit. The
side panel is fixed at the bottom with 1 screw.