5 Configuration
Installation manual
15
EHYHBH05AAV3* + EHYHBH/X08AAV3*
Daikin Altherma hybrid heat pump – heat pump module
4P349587-1F – 2016.10
5.1.2
Basic configuration
Quick wizard: Language / time and date
#
Code
Description
[A.1]
N/A
Language
[1]
N/A
Time and date
Quick wizard: Standard
Space heating/cooling settings
#
Code
Description
[A.2.1.7]
[C-07]
Unit temperature control:
▪ 0 (LWT control): Unit operation is
decided based on the leaving water
temperature.
▪ 1 (Ext RT control): Unit operation is
decided by the external thermostat.
▪ 2 (RT control): Unit operation is
decided
based
on
the
ambient
temperature of the user interface.
[A.2.1.B]
N/A
Only if there are 2 user interfaces:
User interface location:
▪ At unit
▪ In room
[A.2.1.8]
[7-02]
Number of water temperature zones:
▪ 0 (1 LWT zone): Main
▪ 1 (2 LWT zones): Main + additional
[A.2.1.9]
[F-0D]
Pump operation:
▪ 0 (Continuous): Continuous pump
operation, regardless of thermo ON or
OFF condition.
▪ 1 (Sample): When thermo OFF
condition occurs, the pump runs every
5 minutes and the water temperature
is checked. If the water temperature is
below target, unit operation can start.
▪ 2 (Request): Pump operation based
on request.
Example:
Using a room
thermostat and thermostat creates
thermo ON/OFF condition.
Quick wizard: Options
Domestic hot water settings
#
Code
Description
[A.2.2.1]
[E‑05]
Domestic hot water preparation:
▪ 0 (No): NOT possible
▪ 1 (Yes)(default): Possible
[A.2.2.2]
[E‑06]
Domestic hot water production:
▪ 0 (Type 1): by boiler
▪ 1 (Type 2): by tank
Note:
For Switzerland, setting MUST be
"1".
[A.2.2.3]
[E‑07]
Domestic hot water tank:
▪ 4 (Type 5). EKHWP.
▪ 6 (Type 7) Third-party tank.
Range: 0~6.
#
Code
Description
[A.2.2.A]
[D‑02]
Domestic hot water pump (not applicable
for Switzerland):
In case of [E‑06]=0
▪ 0 (No)(default): NOT installed
▪ 1 (Secondary rtrn): Installed for instant
hot water
In case of [E‑06]=1
▪ 0 (No)(default): NOT installed
▪ 1 (Secondary rtrn): Installed for instant
hot water
▪ 2
(Disinf.
shunt):
Installed
for
disinfection
See also illustrations below.
INFORMATION
The tank can be heated via the gas boiler or heat pump.
In case of [E‑06]=0 (not applicable for Switzerland)
Domestic hot water pump installed for instant hot water
c
d
a
b
e
f
g
h
a
Indoor unit
b
Hot water connection on boiler
c
Domestic hot water pump
d
Shower
e
Inlet on boiler
f
Recirculation thermistor (EKTH2)
g
Water supply
h
Non-return valve
In case of [E‑06]=1
Domestic hot water pump installed for…
Instant hot water
Disinfection
c
f
b
a
g
c
b
a
d f
e g
a
Indoor unit
b
Tank
c
Domestic hot water pump
d
Heater element
e
Non‑return valve
f
Shower
g
Cold water
INFORMATION
The correct domestic hot water default settings becomes
only applicable when domestic hot water operation is
activated ([E‑05]=1).
Thermostats and external sensors
NOTICE
If an external room thermostat is used, the external room
thermostat will control the room frost protection. However,
the room frost protection is only possible if the leaving
water temperature control on the unit's user interface is
turned ON.