4 Installation
Installation manual
11
EHYHBH05AAV3* + EHYHBH/X08AAV3*
Daikin Altherma hybrid heat pump – heat pump module
4P349587-1F – 2016.10
4.5.6
To connect the gas meter
INFORMATION
In case of a gas meter with transistor output, check the
polarity. The positive polarity MUST be connected to
X5M/9; the negative polarity to X5M/10.
1
Connect the gas meter cable to the appropriate terminals as
shown in the illustration below.
X1M
9
10
X5M
S3S
2
Fix the cable with cable ties to the cable tie mountings.
4.5.7
To connect the domestic hot water pump
1
Connect the domestic hot water pump cable to the appropriate
terminals as shown in the illustration below.
35
34
X2M
X1M
X5M
1~
M
M2P
2
Fix the cable with cable ties to the cable tie mountings.
4.5.8
To connect the alarm output
1
Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
28
Y1
X2M
X1M
A4P
A8P
X5M
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.5.9
To connect the space cooling/heating ON/
OFF output
1
Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
29
Y2
X2M
X1M
A4P
A8P
X5M
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.5.10
To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.