11.2.2
PQ selection
The PQ number can be selected by switching the digital input signal. The pressure command, the flow rate
command which is set by the parameter in advance can be switched.
In addition, the acceleration / deceleration time of pressure and flow rate when switching the PQ number
can be changed. Refer to the “
Pressure and flow rate change time when the PQ selection switches
”.
By combining DIN2 to DIN5, the pressure and flow rate command value can be selected, as shown in the
following table.
Select the PQ selection number by digital input signal
PQ selection
number
The parameters of the
selected pressure and
flow rate
Details
DIN2
DIN3
DIN4
DIN5
Bit0
Bit1
Bit2
Bit3
0
P13
OFF
OFF
OFF
OFF
1
P14
ON
OFF
OFF
OFF
2
P15
OFF
ON
OFF
OFF
3
P16
ON
ON
OFF
OFF
4
P17
OFF
OFF
ON
OFF
5
P18
ON
OFF
ON
OFF
6
P19
OFF
ON
ON
OFF
7
P20
ON
ON
ON
OFF
8
P21
OFF
OFF
OFF
ON
9
P22
ON
OFF
OFF
ON
10
P23
OFF
ON
OFF
ON
11
P24
ON
ON
OFF
ON
12
P25
OFF
OFF
ON
ON
13
P26
ON
OFF
ON
ON
14
P27
OFF
ON
ON
ON
15
P28
ON
ON
ON
ON