PIM00587
EN-30
CHAPTER 7
HYDRAULIC PIPING
7.1
Piping
Motor pump type (EHU15/30R**00*-03)
There are different port types below for motor pump type. Be sure to connect piping at the all ports. Details
on the piping positions can be found in the outside view drawing. Use hoses for the piping work, and fasten
them with sealing tape.
In addition, the motor pump type is not equipped with an oil cooler. Use the cooling equipment separately
so that they can be used at an appropriate oil temperature.
<Piping Specifications>
Piping Port
Piping Size
Recommended Hose
Withstand Pressure
At Shipment
P
Rc 3/8
EHU**R07 : 10.5 MPa
EHU**R10 : 14.0 MPa
Vinyl cap
DR
Rc 3/8
1.5 MPa
Suction port
G 3/4
1.5 MPa
CAUTION
Make sure the suction pressure is under -0.02MPa. If it becomes more than -0.02MPa, the flow rate may
reduce and the noise may become large.
DR Drain port
Rc 3/8
P Discharge port
Rc 3/8
Arrow view A
Suction port
G 3/4
Arrow view A