NOTICE
Do not move the product while there is oil in the tank (this could cause malfunctions due to oil leakage
or inclusion of air).
3.2
21B
Installation
3.2.1
63B
Install the unit at a well ventilated location where heat will not build up, and secure a surrounding space of
10 cm from each of the four end faces of the unit. Also take care that the temperature of the intake air
complies with the stipulated ambient temperature (40 C max.).
WARNING
If the intake air/exhaust spaces described above are not secured, the heat exchange
function of the oil cooler/DC fan will deteriorate, and the oil temperature and
temperature of the hydraulic devices will become abnormally high, posing a risk of
fire. Be sure to secure the space for air intake /exhaust.
Do not touch hot parts. It can cause burns.
Provide sufficient maintenance space so that working postures will not be
uncomfortable.
At least 10 cm
At least 10 cm
Air intake
Air intake
Exhaust
Air intake
At least 10 cm
At least 10 cm