7/14
Breadcrumb
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
└─
Booster heater
9.4.1
[6-02]
R/W
0~10kW, step: 0,2kW
3kW
9.4.3
[8-03]
R/W
20~95 min, step: 5 min
50 min
9.4.4
[4-03]
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
└─
Emergency
9.5.1
[4-06]
R/W
0: Manual
1: Automatic
2: Auto SH reduced/ DHW ON
3: Auto SH reduced/ DHW OFF
4: Auto SH normal/ DHW OFF
9.5.2
[7-06]
R/W
0: Disabled
1: Enabled
└─
Balancing
9.6.1
[5-02]
R/W
0: OFF
1: ON
9.6.2
[5-03]
R/W
-15~35°C, step: 1°C
0°C
9.6.3
[5-04]
R/W
0~20°C, step: 1°C
10°C
9.6.4
[8-02]
R/W
0~10 hour, step: 0,5 hour
3 hour
9.6.5
[8-00]
R/W
0~20 min, step 1 min
1 min
9.6.6
[8-01]
R/W
5~95 min, step: 5 min
30 min
9.6.7
[8-04]
R/W
0~95 min, step: 5 min
95 min
Installer settings
9.7
[4-04]
R/W
0: Continuous pump operation
1: Non continuous pump operation
2: OFF
└─
Benefit kWh power supply
9.8.2
[D-00]
R/W
0: No
1: Only BSH
2: Only BUH
3: All
9.8.3
[D-05]
R/W
0: No
1: Yes
9.8.4
[D-01]
R/W
0: No
1: Open
2: Closed
3: Smart Grid
9.8.6
R/W
0: No
1: Yes
9.8.7
Enable Room buffering
R/W
0: No
1: Yes
9.8.8
R/W
0~20 kW, step: 0,5 kW
2 kW
└─
Power consumption control
9.9.1
[4-08]
R/W
0: No
1: Continuous
2: Inputs
3: Current Sensor
9.9.2
[4-09]
R/W
0: Amp
1: kW
9.9.3
[5-05]
R/W
0~50 A, step: 1 A
50 A
9.9.4
[5-05]
R/W
0~50 A, step: 1 A
50 A
9.9.5
[5-06]
R/W
0~50 A, step: 1 A
50 A
9.9.6
[5-07]
R/W
0~50 A, step: 1 A
50 A
9.9.7
[5-08]
R/W
0~50 A, step: 1 A
50 A
9.9.8
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.9
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.A
[5-0A]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.B
[5-0B]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.C
[5-0C]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.D
[4-01]
R/W
0: None
1: Booster Heater
2: Backup Heater
9.9.F
[7-07]
R/W
0: No
1: Yes
└─
Energy metering
9.A.1
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
Limit 3
Limit 1
Benefit kWh power supply
Capacity
BSH eco timer
Anti-recycle timer
Limit 2
Allow heater
Allow pump
Power consumption control
Type
Limit
Allow electric heaters
Limit setting kW
HP forced OFF
Space heating priority
Priority temperature
Offset BSH setpoint
Minimum running timer
Maximum running timer
Additional timer
Water pipe freeze prevention
Operation
Emergency
Limit 3
Limit 4
Priority heater
BBR16 activation*
*BBR16 settings are only visible when the language of the user
interface is set to Swedish.
Electricity meter 1
Limit 4
Limit
Limit 2
Limit 1
(*1) EBLA*_(*2) EDLA*_(*3) *23V3_(*4) *2V3
4P685235-1 - 2022.03