11
|
Configuration
Installer reference guide
176
EBLA04~E23V3 + EDLA04~E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05
Value
Description
5~8
Limitation when no actuators. When there is no heating output,
the pump speed limitation is applicable. When there is heating
output, the pump speed is only determined by delta T in
relation to the required capacity. With this limitation range,
delta T is possible and the comfort is guaranteed.
During sampling operation the pump runs for a short time to
measure the water temperatures, which indicate if operation is
required or not.
▪
5:
90% pump speed during sampling
▪
6:
80% pump speed during sampling
▪
7:
70% pump speed during sampling
▪
8:
60% pump speed during sampling
The maximum values depend on the unit type:
[9-0D]=0
[9-0D]=1/5
a (kPa)
b (l/min)
a (kPa)
b (l/min)
a (kPa)
b (l/min)
a (kPa)
b (l/min)
[9-0D]=2/6
[9-0D]=3/7
[9-0D]=4/8
a (kPa)
b (l/min)
a
External static pressure
b
Water flow rate