Item
Description
Flow switch
See installation manual of the flow switch
Wires: 2×0.5 mm²
—
Location extra components
The following illustration shows the location of the extra components that you
need to install on the outdoor unit when using certain option kits.
c
f
a1
b
OR
e
d
a2
a
Accessories in standalone domestic hot water tank (EKHWS*D* and EKHWSU*D*)
a1: Contactor
a2: Terminal block
b
Connection kit for third‑party tank with built‑in thermostat (EKHY3PART2)
c
Flow switch (EKFLSW2)
d
Demand PCB (A8P: EKRP1AHTA)
e
Digital I/O PCB (A4P: EKRP1HBAA)
f
Smart grid relay kit (EKRELSG)
9.2.1 To connect the electrical wiring to the outdoor unit
1
Open the service cover. See
"7.3.2 To open the outdoor unit"
68]. If
necessary, rotate the switch box. See
"7.3.3 To rotate the switch box"
69].
2
Strip insulation (20 mm) from the wires.
a
b
a
Strip wire end to this point
b
An excessive strip length may cause electrical shock or leakage
3
Insert the cables at the back of the unit, and route them through the unit to
the appropriate terminal blocks.