System bus
Input of the basic setting
18
System bus
The heating system
1 - 8 Boiler (modulating or switching)
1 - 15 Mixed weather-dependent heating circuits
0 - 15 Room controller (digital or analogue)
1 Solar system (2 collectors, 2 storage tanks)
1 Solid fuel boiler
Bus ID
For mixer motor controllers and control units
The bus ID (00 - 15; expert level parameter) is used to
number the heating circuits in the system. Each operating
module and each mixer motor module is given the number
of the assigned heating circuit as its bus ID.
Heating circuit numbers (00 - 15) may not be assigned
twice.
Heating circuit numbers 00 and 01 may not be used
simultaneously.
The heating circuits are sequentially numbered starting
with "01".
Please only use heating circuit number 00 for re-
placement controllers if "00" was used in the replaced
controller.
Pre-settings
Heating circuit 1
01
Heating circuit 2
02
!
After setting all the bus ID's the system must be
reenergised (once only).
Input of the basic setting
Input of the basic setting
!
Please ensure that you set the desired operating
mode
after
installation is complete.
!
Please enter the settings in the order specified
(=> priorities).
Operation in normal mode
(operating flap closed)
Operating elements
Ç
Change the set operating mode