![Daikin ARXN25MV1B Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/daikin/arxn25mv1b/arxn25mv1b_service-manual_501334021.webp)
Function & Control
15
2.6 Sleep Mode
SLEEP Mode can be activated by pressing from the remote controller to keep the thermal comfort during
sleeping.
SLEEP Mode continues operation at the target temperature for the
fi
rst one hour, then automatically raises
the target temperature slightly in the case of cooling, or lowers it slightly in the case of heating. This prevents
excessive cooling in summer and excessive heating in winter to ensure comfortable sleeping conditions, and
also conserves electricity.
ON signal of sleep operation
ON signal of sleep opoperation ON signal
OFF signal of sleep operation
operation OFF signal
run
sleep operation
1hr
1hr
(shift 0.5°C)
(shift 1.0°C)
(shift 1.0°C)
(shift 2.0°C)
target temperature
<COOL or DRY>
target temperature
<HEAT>
(no offset on target
temperature)
2.7 Indoor-Outdoor Communication
Master by outdoor unit.
Indoor controller board will transmit signal to outdoor controller board every 0.5s. Outdoor unit will response
to indoor once the valid data is received.
Indoor
Outdoor
If the data communication line between indoor and outdoor disrupted for 15s continuously, compressor will
stop, Outdoor fan stop with fan OFF timer. Indoor LED blinks error.If the communication resumes within 15s,
error code is clear and compressor restarts after 3 minutes.If the communication does not resume after 15s,
unit unable to restart and the error keep blinking.
Содержание ARXN25MV1B
Страница 1: ...SERVICE MANUAL Inverter DOO 0RXQWHG Single Split SM 5WMY A1 R410A ...
Страница 60: ...Wiring Connection 54 4 0 Wiring Connection Model ATXN FTXN 25 35L M ARXN RXN 25 35L M ...
Страница 61: ...Wiring Connection 55 Model ATXN FTXN 50 60L ARXN RXN 50 60L ...
Страница 62: ...Wiring Connection 56 Model ATXN FTXN 50 60M ARXN RXN 50 60M ...