Si12-619A
Table of Contents
v
5.22 Thermistor or Related Abnormality (Outdoor Unit)...............................241
5.23 Electrical Box Temperature Rise..........................................................243
5.24 Radiation Fin Temperature Rise ..........................................................247
5.25 Output Over Current Detection.............................................................251
5.26 Insufficient Gas.....................................................................................253
5.27 Low-voltage Detection or Over-voltage Detection................................257
5.28 Signal Transmission Error (on Outdoor Unit PCB)...............................258
5.29 Anti-icing Function in Other Rooms / Unspecified Voltage
(between Indoor and Outdoor Units) ....................................................259
6. Check ..................................................................................................260
6.1
How to Check .......................................................................................260
Part 7 Removal Procedure ........................................................271
1. Outdoor Unit – E Series (50 / 52 / 58 Class).......................................272
1.1
Removal of the Panels and Plates .......................................................272
1.2
Removal of the Electrical Box ..............................................................277
1.3
Removal of the PCB.............................................................................284
1.4
Removal of the Propeller Fan / Fan Motor ...........................................290
1.5
Removal of the Sound Blanket.............................................................292
1.6
Removal of Electronic Expansion Valve Coil,
Four Way Valve Coil and Thermistor ...................................................296
1.7
Removal of the Distributor....................................................................299
1.8
Removal of the Four Way Valve...........................................................300
1.9
Removal of the Compressor.................................................................301
2. Outdoor Unit – E Series (68 / 71 / 75 Class), D Series .......................303
2.1
Removal of the Outer Panels ...............................................................303
2.2
Removal of the Electrical BOX .............................................................304
2.3
Removal of the PCB.............................................................................308
2.4
Removal of the Fan Motor....................................................................311
2.5
Removal of the Sound Blanket.............................................................312
2.6
Removal of the Four Way Valve Coil, Solenoid Valve Coil,
Electronic Expansion Valve Coil and Thermistor .................................313
2.7
Removal of the Four Way Valve, Solenoid Valve and Shunt ...............315
2.8
Removal of the Solenoid Valve and Shunt...........................................316
2.9
Removal of the Compressor.................................................................317
3. Outdoor Unit – E Series (80 / 90 / 100 Class).....................................318
3.1
Removal of Outer Panels .....................................................................318
3.2
Removal of the Electrical Box ..............................................................334
3.3
Removal of PCB...................................................................................340
3.4
Removal of Fan Motor..........................................................................344
3.5
Removal of Coils / Thermistors ............................................................345
3.6
Removal of Sound Blanket...................................................................351
3.7
Removal of Compressor.......................................................................354
Part 8 Others .............................................................................355
1. Others .................................................................................................356
1.1
Test Run from the Remote Controller ..................................................356
1.2
Jumper Settings ...................................................................................357
1.3
Application of Silicon Grease to a Power Transistor and
a Diode Bridge......................................................................................358
Содержание 3MKS50DVM
Страница 1: ...Si12 619A Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump D Series E Series ...
Страница 13: ...Introduction Si12 619A xii ...
Страница 89: ...Printed Circuit Board Connector Wiring Diagram Si12 619A 76 Printed Circuit Board Connector Wiring Diagram ...
Страница 131: ...Control Specification Si12 619A 118 Function and Control ...
Страница 146: ...Si12 619A Instruction Operation Manual 133 Duct Connected Type Names of parts Indoor Unit 3 6 8 9 10 7 1 4 5 2 ...
Страница 213: ...Instruction Si12 619A 200 Operation Manual ...
Страница 283: ...Check Si12 619A 270 Service Diagnosis ...
Страница 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Страница 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...
Страница 399: ...Si12 619A vi Index ...