Outdoor Unit – E Series (68 / 71 / 75 Class), D Series
Si12-619A
314
Removal Procedure
5
Take off the putty, and
remove each
thermistor.
Place the thermistor so that
its end comes up to the end
of the presser spring.
Be careful not to lose the
presser spring for the
discharge pipe thermistor
.
6
Remove the wire
harness.
S90
:
Outdoor air thermistor
(Blue)
Heat exchanger thermistor
(Gray)
Discharge pipe thermistor
(Black)
S92
:
Gas pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Brown)
Room D (Red)
S93
:
Liquid pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Yellow)
Room D (Blue)
Step
Procedure
Points