Main Functions
Si12-619A
88
Function and Control
1.10
INTELLIGENT EYE
(Wall Mounted Type Only)
This is the function that detects existence of humans in the room by a human motion sensor
(INTELLIGENT EYE) and reduces the capacity when there is no human in the room in order to
save electricity.
Processing
1. Detection method by Intelligent Eye
This sensor detects human motion by receiving infrared rays and displays the pulse wave
output.
A microcomputer in an indoor unit carries out a sampling every 20 msec. and if it detects 10
cycles of the wave in one second in total (corresponding to 20msec.× 10 = 100msec.), it
judges human is in the room as the motion signal is ON.
2. The motions (for example: in cooling)
When a microcomputer doesn’t have a signal from the sensor in 20 minutes, it judges that
nobody is in the room and operates the unit in temperature shifted 2°C from the set
temperature. (Cooling/Dry : 2°C higher, Heating : 2°C lower and Auto : according to the
operation mode at that time.)
★
1 In case of Fan mode, the fan speed reduces by 50 rpm.
If the sensor detects the outputs 10 times/sec.
or more, it judges humans exist.
1sec
sampling (20msec)
High
Low
ON
OFF
Sensor output
(Human motion)
Human detection
signal
(R2821)
ON
OFF
RESET.
Cooling : Set temp. + 2˚C
Heating : Set temp. - 2˚C
Human detection
signal
20 min.
20 min.
within 20
minutes.
40 min.
MaxHz
Mi nHz
0Hz
Compressor
speed
The lower limit by detecting
human.
(Prohibition of thermostat-off)
ON
OFF
ON
OFF
Operation
OFF
Fan speed (
+
1)
Set speed - 50 rpm
Set speed
Set speed
in case of
thermostat-off
Frequency at set temp. + 2˚C
Set temp.
(R4902)
Remote controller
INTELLIGENT
EYE button
Содержание 3MKS50DVM
Страница 1: ...Si12 619A Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump D Series E Series ...
Страница 13: ...Introduction Si12 619A xii ...
Страница 89: ...Printed Circuit Board Connector Wiring Diagram Si12 619A 76 Printed Circuit Board Connector Wiring Diagram ...
Страница 131: ...Control Specification Si12 619A 118 Function and Control ...
Страница 146: ...Si12 619A Instruction Operation Manual 133 Duct Connected Type Names of parts Indoor Unit 3 6 8 9 10 7 1 4 5 2 ...
Страница 213: ...Instruction Si12 619A 200 Operation Manual ...
Страница 283: ...Check Si12 619A 270 Service Diagnosis ...
Страница 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Страница 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...
Страница 399: ...Si12 619A vi Index ...