Instruction
Si12-619A
184
Operation Manual
1. Open the front grille.
2. Remove the air filter.
• Press the claws on the right and left of the air filter down
slightly, then pull upward.
3. Take off the air purifying filter,
Photocatalytic deodorizing filter.
• Hold the tabs of the frame, and remove the claws in 4 places.
4. Clean or replace each filter.
See figure.
5. Set the air filter, air purifying filter
and photocatalytic deodorizing
filter as they were and close the
front grille.
• Operation without air filters may result in troubles
as dust will accumulate inside the indoor unit.
Air Filter
1. Wash the air filters with water or clean them with
vacuum cleaner.
• If the dust does not come off easily, wash them with neutral detergent
thinned with lukewarm water, then dry them up in the shade.
• It is recommended to clean the air filters every two weeks.
Air Purifying Filter (green)
(Replace approximately once every 3 months.)
1. Detach the filter element and attach a new one.
• Insert with the green side up.
• It is recommended to replace the air purifying filter every three months.
Photocatalytic Deodorizing Filter (gray)
[ Maintenance ]
1. Dry the photocatalytic deodorizing filter in the sun.
• After removing the dust with a vacuum cleaner, place the filter in the sun for approximately 6 hours.
By drying the photocatalytic deodorizing filter in the sun, its deodorizing and antibacterial capabilities
are regenerated.
• Because the filter material is paper, it can not be cleaned with water.
• It is recommended dry the filter once every 6 months.
[ Replacement ]
1. Detach the filter element and attach a new one.
Filters
Air filter
Air purifying filter
or photocatalytic
deodorizing filter
Содержание 3MKS50DVM
Страница 1: ...Si12 619A Applied Models Inverter Multi Cooling Only Inverter Multi Heat Pump D Series E Series ...
Страница 13: ...Introduction Si12 619A xii ...
Страница 89: ...Printed Circuit Board Connector Wiring Diagram Si12 619A 76 Printed Circuit Board Connector Wiring Diagram ...
Страница 131: ...Control Specification Si12 619A 118 Function and Control ...
Страница 146: ...Si12 619A Instruction Operation Manual 133 Duct Connected Type Names of parts Indoor Unit 3 6 8 9 10 7 1 4 5 2 ...
Страница 213: ...Instruction Si12 619A 200 Operation Manual ...
Страница 283: ...Check Si12 619A 270 Service Diagnosis ...
Страница 302: ...Si12 619A Outdoor Unit E Series 50 52 58 Class Removal Procedure 289 Step Procedure Points ...
Страница 385: ...Wiring Diagrams Si12 619A 372 Appendix FTK X S50 60 71FVLT ...
Страница 399: ...Si12 619A vi Index ...