Web Operation 71
PTZ setup
Figure 4-50
Configure PTZ parameters. See Table 4-10.
Step 2
Table 4-10 PTZ parameter description
Parameter
Description
Device Type
Select device type to be controlled. It is
Local
by default.
Slot
Select corresponding slot.
Channel
Select channel to be configured.
Port
Select corresponding port.
PTZ Type
Support local PTZ only.
Protocol
Select device protocol; keep consistent with camera.
Address
Set device address, ranging from 0 to 255.
Baud Rate
Set baud rate of device; keep consistent with camera.
Data Bit
Set device data bit, including 5, 6, 7 and 8.
Stop Bit
Set device stop bit, including stop bit 1 and stop bit 2.
Parity
Include odd, even, flag parity and empty parity. Keep consistent with
camera parity.
Click
Save
to save configuration.
Step 3
4.5.1.9 Comm Setup
After comm parameters are set, the video matrix platform can connect other devices through
comm ports, for the purpose of debugging and operation.
Select
Setup > System Config > Comm Setup
.
Step 1
The
Comm Setup
interface is displayed. See Figure 4-51.